Specifications
Aries and Compax3 EPL Drive
Aries EPL Compax3 EPL
Drive Current, SxxxV2: 2.5, 6.3, 10, 15
continuous (A 3, 4.5, 6.3 SxxxV4: 3.8, 7.5, 15, 30
RMS) HxxxV4: 50, 90, 125, 155
SxxxV2: 5, 12.6, 20, 30
Power Output Drive Current, 9, 13.5, 14.2 SxxxV4: 7.6, 15, 30, 60
peak (A RMS)
HxxxV4: 75, 135, 188, 233
Commutation Sinusoidal Sinusoidal
PWM Frequency 16 or 32 kHz, motor dependent 8/16/32 kHz, model dependent
SxxxV2: 80–253 VAC;
Power Input 120/240 VAC SxxxV4: 80–528 VAC;
HxxxV4: 350–528 VAC
Control Power Input 120/240 VAC, required 24VDC, required
Torque Loop 62.5 μsec 62.5 μsec
update
Velocity Loop
Performance 125 μsec 125 μsec
update
Position Loop
update 125 μsec 125 μsec
Communications Ethernet, ETHERNET Powerlink RS232/485, ETHERNET Powerlink
8–20 programmable inputs, sinking,
Digital inputs 7 programmable inputs, 5–24 VDC
24 V nom. @ 10 mA
Inputs Analog inputs N/A 2 (dedicated); 14-bit
Encoder input 2 MHz (pre-quadrature) 5 MHz (pre-quadrature)
Safety input EN954-1 CAT3
Digital outputs 4 programmable outputs 4–16 programmable outputs
Two (dedicated); 8 bit; software
Analog outputs N/A
Outputs configurable as monitor outputs
5–24 VDC solid state, N.O.,
Fault Brake N.O., 1.6 A @ 24 VDC max
1 amp @ 24 VDC max
Incremental encoder, Incremental encoder, resolver,
Feedback Parker smart encoder, EnDat and Hiperface absolute
EnDat 2.1 absolute encoder encoder
0–45°C (32–113°F)
Temperature 0–45°C (32–113°F)
Environmental except AR-13, 0–40°C (32–104°F)
Humidity 0–95%, non-condensing 0–85%, non-condensing
Internal capacitance, internal Internal capacitance, internal
Regeneration circuitry to accommodate external circuitry to accommodate external
resistor resistor
UL Recognized, CE (EMC), UL and cUL Recognized,
Standards
CE (LVD) CE (EMC), CE (LVD)
More detailed specifications are available in the product manuals at parkermotion.com
12 Parker Hannifin Corporation • Electromechanical Automation Division • 800-358-9070 • www.parkermotion.com