Catalog HY15-3502/US                              Proportional Flow Regulator Valve
                   Technical Information                             Series JP04C 21

            CV
                   General Description
                   2 Way, Normally Closed, Proportional Flow Regulator
                   Valve. Pressure Compensated. For additional informa-
            Valves
              Check
            SH     tion see Technical Tips on pages PV1-PV6.


                   Features
            Valves
              Shuttle
            LM     •  One piece cartridge housing ensures internal
                     concentricity
                   •  Coil: Waterproof, hermetically sealed, requires no
                     O’Rings; Symmetrical coil can be reversed without
                                                                                                  (3)
                     affecting performance.
            Controls
              Load/Motor
            FC                                                                 (2)
                   •  Nonmagnetic spool and housing assembly
                   •  Factory-adjusted low variation option (Model “L”) is                        (2)
                     available for applications where low variation of flow from
                     valve to valve is essential at a given current.           (3)
              Flow
            Controls
            PC                                                                                          Port (1)
                                                                                                       Is Not Used
                                                                       Performance Curves
              Pressure
            Controls
                                                                        PWM Current Regulator Recommended
            LE     Specifications
                                                                       Flow vs. Input Signal
                                                                        GPM LPM        Hydraulic Oil 150 SSU @ 100°F (32 cSt)
                    Rated Flow        21    30 LPM (8 GPM)
                                                                         12  45.4
                                            Standard (‘SS’ Coil)
                                      21    36 LPM (9.5 GPM)                                              "SP" Coil
            Elements
              Logic
            DC                              High Flow (‘SP’ Coil)         8  30.3
                                                                         Flow
                    Maximum Input     210 Bar (3000 PSI)                                                  "SS" Coil
                    Pressure At Port 2                                    4  15.1
                    Minimum Pressure  21    13.8 Bar (200 PSI) Standard
            Controls
              Directional
                                                                            0
            MV      Differential      21    20.7 Bar (300 PSI) High Flow               20      40      60      80     100
                                                                               0
                    Maximum Internal  780 cc (46 cu. in.)                                    Input Current (%)
                    Leakage           @ 210 Bar (3000 PSI)
                    Hysteresis @      7%                               Flow Regulation (Measured 75% of Rated Current)
              Manual
            Valves
            SV      100 Hz PWM                                          GPM LPM        Hydraulic Oil 150 SSU @ 100°F (32 cSt)
                    Cracking Pressure  25% of Input Signal               12  45.4
                                                                                                           JP04C 21 ("SP" Coil)
                    Variation of Flow  Standard Model
                    @ 35% of Rated    Up To ±20% Of Rated Flow           Flow  8  30.3                     JP04C 21 ("SS" Coil)
              Solenoid
            Valves
            PV      Current           Model “L”
                                      ±7% Of Rated Flow                   4  15.1
                    Cartridge Material  All parts steel. All operating
                                                                            0
                                      parts hardened steel.                  Bar      35    70    105    140    175   210
                                                                               0
              Proportional
            Valves
                                                                             PSI     500   1000   1500   2000  2500   3000
                    Operating Temp.   -40°C to +93.3°C (Nitrile)
            CE                                                                                  Pressure
                    Range/Seals       (-40°F to +200°F)
                                      -31.7°C to +121.1°C (Fluorocarbon)
                                      (-25°F to +250°F)                Pressure Drop vs. Flow
                                                                          PSI Bar      Hydraulic Oil 150 SSU @ 100°F (32 cSt)
                    Fluid             Mineral-based or synthetic with
              Coils &
            Electronics
            BC      Compatibility/    lubricating properties at viscosities  300  20.7
                    Viscosity         of 45 to 2000 SSU (6 to 420 cSt)          Measured when valve is fully open
                                                                                @ 75% of rated current
                                                                                                           'SP'
                    Filtration        ISO Code 16/13,                    Pressure  200  13.8               Coil
                                      SAE Class 4 or better              100  6.9
            Cavities
              Bodies &
            TD      Approx. Weight    .13 kg (.28 lbs.)                                       'SS' Coil
                                                                            0
                    Cavity            3X                                     LPM     7.6    15.2  22.7   30.4   37.8  45.0
                                                                               0
                                      (See BC Section for more details)     GPM       2      4     6      8     10     12
                                                                                                  Flow
              Technical
            Data
                                                                   PV37                        Parker Hannifin Corporation
                                                                                               Hydraulic Cartridge Systems
   33   34   35   36   37   38   39   40   41   42   43