Page 42 - Parker - Proportional Valves
P. 42

Catalog HY15-3502/US                              Proportional Flow Regulator Valve
                   Technical Information                             Series HP02P 21

            CV
                   General Description
                   2 Way, Normally Open, Proportional Flow Regulator
                   Valve. Partially Pressure Compensated. For additional
            Valves
              Check
            SH     information see Technical Tips on pages PV1-PV6.
                   Features
                   •  Analog Proportional Partially Pressure Compensated
                     Flow Regulator regulates flow proportionally to the input
            Valves
              Shuttle
            LM       solenoid current
                   •  The valve is designed to be used in applications where
                     fine pressure compensation is not required and an
                     economical solution is important                                            (2)
                   •  One piece cartridge housing ensures internal
            Controls
              Load/Motor
            FC       concentricity                                             (1)
                   •  Coil: Waterproof, hermetically sealed, requires no                               (1)
                     O’Rings; Symmetrical coil can be reversed without
                     affecting performance.
                                                                               (2)
              Flow
            Controls
                   •  Nonmagnetic spool and housing assembly
            PC
                   •  Factory-adjusted low variation option (Model “L”) is
                     available for applications where low variation of flow from
                     valve to valve is essential at a given current or when an
                     external pressure compensator is used.
            Controls
              Pressure
            LE                                                         Performance Curves
                   Specifications                                       PWM Current Regulator Recommended
                                                                       Flow vs. Input Current
                    Rated Flow @      2 to 1 19 LPM (5 GPM)
                                                                         GPM LPM       Hydraulic Oil 150 SSU @ 100°F (32 cSt)
            Elements
              Logic
                    210 Bar (3000 PSI)                                    6  22.8
            DC
                    Preferable Input  Port 1
                    Port For Best
                    Hysteresis
                                                                          4  15.2
              Directional
            Controls
                    Hysteresis @      <10%
            MV      100 Hz PWM                                           Flow               2 to 1 OR 1 to 2
                    Variation of Flow  Standard Model                     2  7.6
                    @ 35% of Rated    Up To ±20% Of Rated Flow
                    Current & Constant Model “L”
            Valves
              Manual
            SV      ∆ ∆ ∆ ∆ ∆P Maintained By  ±7% Of Rated Flow
                    Pressure                                               0
                                                                                       20      40      60      80     100
                    Compensator                                                0
                    Cartridge Material  All parts steel. All operating                       Input Current (%)
                                      parts hardened steel.
              Solenoid
            Valves
            PV                                                         Flow Regulation (Measured at De-Energized Coil)
                    Operating Temp.   -40°C to +93.3°C (Nitrile)
                                                                         GPM LPM       Hydraulic Oil 150 SSU @ 100°F (32 cSt)
                    Range/Seals       (-40°F to +200°F)                   8  30.4
                                      -31.7°C to +121.1°C (Fluorocarbon)
                                      (-25°F to +250°F)
                                                                                                      2 to 1
            Valves
              Proportional
            CE      Fluid             Mineral-based or synthetic with     6  22.8
                    Compatibility/    lubricating properties at viscosities                           1 to 2
                    Viscosity         of 45 to 2000 SSU (6 to 420 cSt)   Flow  4  15.2
                    Filtration        ISO Code 16/13,
                                      SAE Class 4 or better
            Electronics
              Coils &
            BC
                    Approx. Weight    .08 kg (.17 lbs.)                   2  7.6
                    Cavity            2X
                                      (See BC Section for more details)    0
                                                                             Bar      35    70    105    140    175   210
              Bodies &
            Cavities
                                                                               0
            TD                                                               PSI     500   1000   1500   2000  2500   3000
                                                                                                Pressure
              Technical
            Data
                                                                   PV41                        Parker Hannifin Corporation
                                                                                               Hydraulic Cartridge Systems
   37   38   39   40   41   42   43   44   45   46   47