Page 27 - Parker - Energy Products Division - Multitube (Instrument and Heat Trace Tubing Products)
P. 27
Chemical Processing and Refineries
Catalog Number 4200-M-2
Back to Table of Contents
SH – Self-Regulating High Temperature
Maintenance Bundles
Maintain Temperatures up to 250˚F (121˚C) and withstands an Internal
Exposure Temperature of 400˚F (204˚C)
General Common Tube Materials and Sizes
Parflex Temptrace tubing is thermally insulated with a Temptrace is readily available in 1⁄4”, 3/8” and 1⁄2”
TM
TM
non-hygroscopic inorganic fiberglass material sizes as well as metric sizes. (6 mm, 8mm, 10mm
and protected with a flexible black flame-resistant and 12mm) The most common stock alloys are
PVC jacket. copper type #122 DHP seamless ASTM B68, B75, as
well as seamless and welded stainless steel tubing
Parflex standard Temptrace is thermally insulated 316/316L ASTM A269. Many other alloys, ASTM
TM
for transfer of fluids or gases up to 400°F (204°C) while standards and sizes are available upon request. (See
maintaining an outer jacket surface temperature of Technical Data Section)
140°F (60°C), meeting NEC Personnel Protection
Code 427.12. Testing
All Temptrace products are pressure tested prior
TM
SH- Temptrace is designed to provide temperature to shipment. Third party testing and witnessing is
TM
maintenance for gases, liquids or other process available upon request, including DNV, ABS and
materials. The high temperature self-regulating product Lloyd’s Register. Contact factory for complete details.
has a maximum temperature rating of 250°F (121.1°C),
power-on, and can be steam cleaned at 400°F (204°C), Jacketing Materials
power-off and is T3 rated for 3, 5 & 8W. T2D 10, 15, 20W. Black UV resistant FR-PVC is our standard material,
however other jacketing materials are available upon
SH- Temptrace can maintain process tube request, including non-halogenated FR-TPE and
TM
temperatures up to 250°F (121.1°C), depending upon Urethanes. (See Technical Data Section)
ambient conditions.
NOTE: It is absolutely necessary to seal the ends against
contamination from moisture and/or corrosive liquids. Parker
Heating Cables
Hannifin cannot assume any liability for product damage caused by
Cables are available in 120V and 208-277 volt, with moisture from unsealed ends.
Heat outputs of 5, 10, 15 and 20 watt/ft.
Parflex standard SH designs all come with an internal
tinned copper braid on heating cable for grounding
purpose and a Fluoropolymer jacket over the heating
cable to provide additional protection against many
harsh environments.
Parker Hannifin Corporation
23 24 Energy Products Division