Page 40 - Parker - Rodless Air Cylinders
P. 40
Catalog #AU03-0928/NA Rodless Air Cylinders
Shock Absorbers P1X Series
Performance Data (40 - 63mm Bores)
Air Cushion w/back
pressure (flow controls or
other meter out device)
Shock Absorber
40 mm Bore 50 mm Bore
100 100
Velocity (inches/sec) 10 Velocity (inches/sec) 10
1 1
1 10 100 1000 1 10 100 1000
Load (lbs) Load (lbs)
63 mm Bore
100
Velocity (inches/sec) 10
1
1 10 100 1000
Load (lbs)
Notes: 1. If the cylinder is vertical in orientation, double the total load for bottom shock absorber.
2. Use the total load that is being moved by shock absorber. If a weight transfer application, this would include La.
3. If final velocity cannot be easily determined, use two times the stroke divided by the stroke time.
Parker Hannifin Corporation
32 Actuator Division
Wadsworth, OH 44281