Page 88 - Parker - Rodless Air Cylinders
P. 88

Catalog #AU03-0928/NA                             Rodless Magnetic Cylinders
            Guided Version/Options                            P1Z Series


            Courbes
            Optional External Adjustable Bumpers

            Dimensions

                                                                                             B






                  NN  E                                                     E    NN


                                                                                            C

                            AA                                      AB                            D





             Ø    AA     AB     B      C     D     E      NN
                  7.5    6.5    12    10     14    4
             16                                         M10 x 1
                 (0.30)  (0.26) (0.47) (0.39) (0.55) (0.16)
                  10      10    11    14.5   18    4
             20                                         M14 x 1.5
                 (0.39)  (0.39) (0.43) (0.57) (0.71) (0.16)
                  11      12    20    18     26    8
             32                                         M20 x 1.5
                 (0.43)  (0.47) (0.79) (0.71) (1.02) (0.31)



            External Hydraulic Shock Absorbers


            Loads / Speeds diagram                                                 Speed (in/s)
                                                                      0        4        8       12       16
                                                                   35
                                                                           Ø 32
                                                                   30                                       66
            The diagram to the right exhibits the P1Z cylinders
                                                                 Load (kg)  20                              44  Load (lbs.)
            maximum capacities with an adjustable bumper.          25
            If the intersection exhibits between speed and load is  15
            above the curves, it is imperative to use hydraulic shock      Ø 20
                                                                   10                                       22
            absorbers to prevent cylinder damage.                          Ø 16
                                                                    5
                                                                    0
                                                                      0       0.1      0.2      0.3      0.4
                                                                                   Speed (m/s)



            Example:
                     Ø 32 mm cylinder with a 0.3 m/s speed and 25 kg load
                     Choose the hydraulic shock absorber option

                     Ø 20mm cylinder with  0.2 m/s speed and 10 kg load

                     Choose the adjustable bumpers option




                                                                                         Parker Hannifin Corporation
                                                              80                         Actuator Division
                                                                                         Wadsworth, OH  44281
   83   84   85   86   87   88   89   90   91   92   93