Page 85 - Parker - Rodless Air Cylinders
P. 85
Catalog #AU03-0928/NA Rodless Magnetic Cylinders
Guided Version/Technical Data P1Z Series
Pressure in the Cylinder / Pneumatic Holding Force
Pressure (PSI)
29 44 58 73 87 102
500 112 Example:
450
400 Ø 32 90 Pressure: 5 bar (73 PSI)
350
F = 322 N (72 lbs.) for Ø 32 mm cylinder
300 67 max
(N) 250 (Lbs.)
200 Ø 20 44
150 Calculate the kinetic energy due to the load moved.
100 Ø 16 22 Acceleration or deceleration should not exceed the magnetic
50 coupling force of cylinder.
0 0
2 3 4 5 6 7
Pressure (bar)
Loads Diagram
Permissible radial loads, horizontal mounting
Ø 32
“L” Ø Max.
L (lbs.)
Load “L” (kg) Ø 20 16 12 15
(kg)
7
26
20
Ø 16
32 30 66
Stroke (mm)
Permissible axial loads, horizontal mounting
M = Fx Zf Ms = Fy Zf Mv = Fx Yf E
* * *
“Fx”
“Fx” “Fy”
Yf
Zf Zf
Ø Max. Max. Max.
moment M moment Ms moment Mv
(Nm) (in-lbs.) (Nm) (in-lbs.) (Nm) (in-lbs.)
16 2.4 21 0.5 4.4 2.4 21
20 5 44 1 8.9 5 44
32 15 133 3 26.6 15 133
Parker Hannifin Corporation
77 Actuator Division
Wadsworth, OH 44281