Page 85 - Parker - Rodless Air Cylinders
P. 85

Catalog #AU03-0928/NA                             Rodless Magnetic Cylinders
            Guided Version/Technical Data                     P1Z Series


            Pressure in the Cylinder / Pneumatic Holding Force

                               Pressure (PSI)
                 29     44      58     73     87     102
              500                                      112     Example:
              450
              400                             Ø 32       90    Pressure: 5 bar (73 PSI)
              350
                                                               F    = 322 N (72 lbs.) for Ø 32 mm cylinder
              300                                        67     max
             (N)  250                                      (Lbs.)
              200                             Ø 20       44
              150                                                      Calculate the kinetic energy due to the load moved.
              100                             Ø 16       22    Acceleration or deceleration should not exceed the magnetic
               50                                              coupling force of cylinder.
                0                                         0
                 2       3      4      5       6      7
                               Pressure (bar)


            Loads Diagram

            Permissible radial loads, horizontal mounting

                                                                   Ø 32
                        “L”                                                                    Ø              Max.
                                                                                                                L  (lbs.)
                                                             Load “L” (kg)    Ø 20            16     12    15
                                                                                                      (kg)

                                                                                                       7

                                                                                                             26
                                                                                                20
                                                                   Ø 16

                                                                                                32     30    66


                                                                        Stroke (mm)
            Permissible axial loads, horizontal mounting


                        M = Fx   Zf                       Ms = Fy   Zf                      Mv = Fx   Yf              E
                              *                                  *                                  *
                                                                                     “Fx”
                “Fx”                                “Fy”
                                                                                        Yf
                  Zf                                  Zf












             Ø          Max.           Max.             Max.
                     moment M        moment Ms        moment Mv
                  (Nm)   (in-lbs.)  (Nm)  (in-lbs.)  (Nm)  (in-lbs.)
             16    2.4     21       0.5     4.4      2.4     21
             20     5      44       1       8.9       5      44
             32    15     133       3      26.6      15      133




                                                                                         Parker Hannifin Corporation
                                                              77                         Actuator Division
                                                                                         Wadsworth, OH  44281
   80   81   82   83   84   85   86   87   88   89   90