Page 19 - Parker - Republic/Manatrol (Hydraulic and Pneumatic Control Valves)
P. 19

Catalog HY14-3000/US                              Exectrol Directional Control Valves
            Technical Information                             Series 21100


            General Description
            Series 21100 Exectrol directional control valves are
            direct solenoid operated 4-way control valves. A slide
            and balanced seals are used which provides near zero
            leakage. The valves have a high tolerance to media
            contamination as each movement of the slide wipes                                     ★ ★
      B     the sealing surfaces clean which in turn results in long

            service life.



            Features
            •   Shear-type positive seal.
            •   Zero leakage (8 drops per min. maximum).
            •   Ideal for water soluble systems (95-5).
            •   Pressures up to 414 Bar (6000 PSI).
            •   Long life, easy maintenance.
            •   Standard valves are interflow.
            •   No packing to wear or cut.
            •   High tolerance to contamination.
            •   High tolerance to silting.
            •   Manual overides are standard.





            Specifications

              Service     Hydraulic oil. Water containing minimum of     Internal   8 drops per min. maximum
              Applications  5% soluble oil. Suggest water soluble oil      Leakage
                          with a sodium sulphonate-based emulsifier.      Mounting   Subplate. Mounting bolts furnished
                          Oil should have a viscosity of 250-350 SSU
                          at 38°C (100°F). Others available on      Material   Cover, Body,
                          special order.                                    Bottom Plate,
                                                                            Inserts, Washers,  Steel
              Maximum     Working:  414 Bar (6000 PSI)                      Spring Retainer,
              Operating   *Proof:   621 Bar (9000 PSI)                      Screws,
              Pressure    *Burst:   1035 Bar (15,000 PSI)                   Retainer Plate:
                          *Applicable to pressure and cylinder ports         Name Plate,    Aluminum alloy,
                          only                                              End Cap,        anodized
                          Note: Installation of this valve should           Retainer Plate:
                          ensure that exhaust port pressure does not        Slide, Seals,
                          exceed cylinder port pressures by more            Springs,        Stainless Steel
                          than 3.5 Bar (50 PSI) and never exceed            Pilot Choke Plug:
                          69 Bar (1000 PSI)                                 O-rings:        Synthetic rubber
              Flow        11.4 LPM (3 GPM) rated maximum
                                                                Operating   -40°C to +107°C (-40°F to +225°F)
              CV Factor   0.28                                  Temperature  (with Code 02 O-rings)














            3000-B1.p65, dd
                                                             B2                        Parker Hannifin Corporation
                                                                                       Hydraulic Valve Division
                                                                                       Elyria, Ohio, USA
   14   15   16   17   18   19   20   21   22   23   24