Page 21 - Parker - Republic/Manatrol (Hydraulic and Pneumatic Control Valves)
P. 21

Catalog HY14-3000/US                              Exectrol Directional Control Valves
            Technical Information                             Series 21200


            General Description
            Series 21200 Exectrol directional control valves are
            direct solenoid operated 4-way control valves. A slide
            and balanced seals are used which provides near zero
            leakage. The valves have a high tolerance to media
            contamination as each movement of the slide wipes                                     ★ ★
      B     the sealing surfaces clean which in turn results in long

            service life.




            Features
            •   Shear-type positive seal.
            •   Zero leakage (8 drops per min. Max. – Test pressure
              276 Bar (4000 PSI).
            •   Ideal for water soluble systems (95-5).
            •   Pressures up to 414 Bar (6000 PSI).
            •   Long life, easy maintenance.
            •   Standard valves are interflow.
            •   No packing to wear or cut.
            •   High tolerance to contamination.
            •   High tolerance to silting.
            •   Manual overides are standard.





            Specifications
              Service     Hydraulic oil. Water containing minimum of     Internal   8 DPM Max. at 276 Bar (4000 PSI)
              Applications  5% soluble oil. Suggest water soluble oil      Leakage
                          with a sodium sulphonate-based emulsifier.
                          Oil should have a viscosity of 250-350 SSU     Mounting   Subplate. Mounting bolts furnished
                          at 38°C (100°F). Others available on      Material   Cover:     Steel
                          special order.                                    Body:         Steel
              Maximum     Working:  414 Bar (6000 PSI)                      Bottom Plate:   Steel
              Operating   *Proof:   621 Bar (9000 PSI)                      Inserts:      Steel
              Pressure    *Burst:   1035 Bar (15,000 PSI)                   Washers:      Steel
                                                                            Locknut:      Steel
                          *Applicable to pressure and cylinder ports         Spring Retainer:  Steel
                          only                                              Screws:       Steel
                          Note: Installation of this valve should           Retainer Plate:  Steel
                          ensure that exhaust port pressure does not        Name Plate
                          exceed cylinder port pressures by more            Housing:      Aluminum alloy, anodized
                          than 3.5 Bar (50 PSI) and never exceed            End Cap:      Aluminum alloy, anodized
                          69 Bar (1000 PSI)                                 Slide:        Stainless Steel
              Flow        37.9 LPM (10 GPM) rated maximum                   Seals:        Stainless Steel
              Operating    25 milliseconds                                  Springs:      Stainless Steel
              Time                                                          O-rings:      Synthetic rubber
              CV Factor   1.0                                   Operating   -40°C to +107°C (-40°F to +225°F)
                                                                Temperature  (with Code 02 O-rings)








            3000-B1.p65, dd
                                                             B4                        Parker Hannifin Corporation
                                                                                       Hydraulic Valve Division
                                                                                       Elyria, Ohio, USA