Page 40 - Parker - Hydraulic Motor/Pump
P. 40
Catalogue HY30-8249/UK Hydraulic motor/pump
Specifications Series F12
Frame size F12 -030 -040 -060 -080 -090 -110 -125 -150 -250
Displacement [cm /rev] 30.0 40.0 59.8 80.4 93.0 110.1 125.0 150 242
3
Operating pressure
max intermittent [bar] 480 480 480 480 420 480 480 420 420
1)
max continuous [bar] 420 420 420 420 350 420 420 350 350
Motor operating speed [rpm]
max intermittent 1) 7 300 6 700 5 800 5 300 5 000 4 800 4 600 3 500 3 000
max continuous 3) 6 700 6 100 5 300 4 800 4 600 4 400 4 200 3 200 2 700
min continuous 50 50 50 50 50 50 50 50 50
Max pump selfpriming speed
2)
L or R function; max [rpm] 3150 2870 2500 2300 2 250 2200 2 100 1 700 1 500
Motor input flow
1)
max intermittent [l/min] 219 268 347 426 465 528 575 525 726
max continuous [l/min] 201 244 317 386 428 484 525 480 653
3)
Drain temperature , max [°C] 115 115 115 115 115 115 115 115 115
min [°C] -40 -40 -40 -40 -40 -40 -40 -40 -40
Theoretical torque at 100 bar [Nm] 47.6 63.5 94.9 127.6 147.6 174.8 198.4 238.1 384.1
Mass moment of inertia
2
(x10 ) [kg m ] 1.7 2.9 5 8.4 8.4 11.2 11.2 40 46
-3
Weight [kg] 12 16.5 21 26 26 36 36 70 77
1) Intermittent: max 6 seconds in any one minute.
2) Selfpriming speed valid at sea level. Find more info on page 42
3) See also installation information. Page 67
40 Parker Hannifin
Pump and Motor Division
Trollhättan, Sweden