Page 40 - Parker - Hydraulic Motor/Pump
P. 40

Catalogue HY30-8249/UK                             Hydraulic motor/pump
        Specifications                                     Series F12


                            Frame size F12   -030   -040   -060    -080   -090   -110    -125   -150    -250
                    Displacement  [cm /rev]  30.0   40.0   59.8    80.4   93.0   110.1  125.0    150    242
                                      3
                        Operating pressure
                      max intermittent   [bar]  480  480    480    480    420     480    480     420    420
                                    1)
                       max continuous  [bar]  420   420     420    420    350     420    420     350    350
               Motor operating speed  [rpm]
                          max intermittent  1)  7 300  6 700  5 800  5 300  5 000  4 800  4 600  3 500  3 000
                          max continuous  3)  6 700  6 100  5 300  4 800  4 600  4 400  4 200   3 200  2 700
                             min continuous   50     50     50      50     50     50      50     50     50
             Max pump selfpriming speed
                                         2)
                   L or R function; max  [rpm]  3150  2870  2500   2300   2 250  2200   2 100   1 700  1 500
                           Motor input flow
                                  1)
                    max intermittent   [l/min]  219  268    347    426    465     528    575     525    726
                      max continuous  [l/min]  201  244     317    386    428     484    525     480    653
                                3)
               Drain temperature , max  [°C]  115   115     115    115    115     115    115     115    115
                                  min  [°C]  -40     -40    -40    -40     -40    -40    -40     -40    -40
          Theoretical torque at 100 bar [Nm]  47.6  63.5   94.9   127.6   147.6  174.8  198.4   238.1  384.1
                    Mass moment of inertia
                                         2
                              (x10 )  [kg m ]  1.7   2.9     5     8.4     8.4    11.2   11.2    40     46
                                  -3
                                Weight [kg]   12    16.5    21      26     26     36      36     70     77
                                       1) Intermittent: max 6 seconds in any one minute.
                                       2) Selfpriming speed valid at sea level. Find more info on page 42
                                       3) See also installation information. Page 67











































                                                          40                        Parker Hannifin
                                                                                    Pump and Motor Division
                                                                                    Trollhättan, Sweden
   35   36   37   38   39   40   41   42   43   44   45