Catalogue HY30-8249/UK                             Hydraulic motor/pump
        Technical information                              Series F12

        Selfpriming speed and required
        inlet pressure                                       Inlet pressure     F12 Pump
                                                             [bar]
        Series F12                                                   F12-250-150-125 -110 -90 -80  -60 -40 -30
        When operating the F12 as a pump (with L or R valve   2,0
        plate) above the selfpriming speed, the inlet must be
        pressurized. Increased noise and deteriorating perform-  1,5
        ance may otherwise be experienced.
        Diagrams 2 and 3 shows required pump inlet pressure
        vs. shaft speed.                                     1,0
        The F12 motor (type M valve plate) sometimes operates
        as a pump e.g. when used in a propel transmission and   0,5
        the vehicle is going downhill.
        Minimum required inlet pressure versus shaft speed is
        shown in the diagrams.                                 0
        The inlet pressure can be charged by external pump,                            0,15 bar vacuum
        pressurized reservoir or using BLA Boost unit.       -0,5
        Find more info about the BLA unit at page 66.          1000      2000     3000     4000     5000
                                                                                               Speed [rpm]
                                                            Diagram 2. Min. required pump (F12-L or -R) inlet press.


                                                             Inlet pressure     F12 Motor
                                                             [bar]
                                                                   F12-250-150-125 -110 -90  -80 -60  -40  -30
                                                             2,0

                                                             1,5


                                                             1,0

                                                             0,5


                                                               0
                                                                                    0,15 bar vacuum
                                                             -0,5
                                                                    1000     2000     3000     4000
                                                                                             Speed [rpm]

                                                            Diagram 3. Min. required motor (F12-M) inlet pressure.























                                                          42                        Parker Hannifin
                                                                                    Pump and Motor Division
                                                                                    Trollhättan, Sweden
   37   38   39   40   41   42   43   44   45   46   47