Page 90 - Parker - AC and DC drives and motors
P. 90

DC Drives - Integrator Series


         DRV and Chassis Types - 575V and 690V
         Electrical Characteristics





                      Part Number                           AC Line Voltage   HP
                                                                                       Max Amps       Frame
             Type     Non-Regenerative    Regenerative
             DRV      955+CN0500-A4       955+CR0500-A4          575          500         700           4
                      955+CN0500-D4       955+CR0500-D4          575          500         700           4
                      955+CN0600-A4       955+CR0600-A4          575          600         815           4
                      955+CN0600-D4       955+CR0600-D4          575          600         815           4
                      955+CN0900-D6       955+CR0900-D6          575          900        1200           6
                      955+CN1200-D6       955+CR1200-D6          575         1200        1600           6
                      955+CN1350-D6       955+CR1350-D6          575         1350        1850           6
                      955+CN1500          955+CR1500             575         1500        2000           H
                      955+CN1750          955+CR1750             575         1750        2400           H
             Chassis  591+1250/690*       590+1250/690*          690         1100        1250           6
                      591+1600/690*       590+1600/690*          690         1400        1600           6
                      591+1950/690*       590+1950/690*          690         1600        1850           6
                      591+2000/690*       590+2000/690*          690         1750        2000           H
                      591+2400/690*       590+2400/690*          690         2000        2400           H
                      * Frame 6 and frame H units are not UL or cUL listed.

           Accessories and Options


            Category                                                                                       Page
            Operator Interface
            While every DC590+ is shipped with a keypad/display, there are several options available such as a remote keypad kit and a full   93
            featured graphical display. In addition, the TS8000 series HMI is fully compatible with the DC590+.
            Communication Cards
            A wide variety of communications cards allow the DC590+ series drives to interface with most current and legacy SCADA
            networks, using both open architecture and proprietary standards. Other cards allow multiple drives to communicate with   94
            each other, peer to peer. Field or factory installed.
            Speed Feedback Cards
            A number of option cards for popular feedback devices are offered. Field or factory installed.  95
            Control Transformer
            When a source of 110V control power is needed, this option can be added to certain sizes of DC590+ DRV.  95
            Blower Motor Starters
            For DC motors with force ventilation, this option provides a means of protection for the blower motor.  95
            Dynamic Braking
            For applications requiring dynamic braking, pre-selected resistors are offered. The kits are designed for stopping a motor at full
            load current from base speed with two times motor energy, three times in rapid succession (NEMA ICS 3-302.62 dynamic brak-  96
            ing stop option) For more frequent or continuous braking, consider a regenerative style DC590+.
            Contactors
            To add application flexibility, contactor options are available for many DC590+ sizes.          96
            Accessories - Power Quality
            Pre-selected line/load reactors and EMC filters can be provided for the DC590+ series.          112





                                                              90