Page 11 - Eaton - Automatic self-cleaning strainers
P. 11

Model 2596 Automatic Self-Cleaning Strainers
                      Control



                      Systems


                      & Elements









           Eaton Automatic Control Systems (ACS) are              mOdES OF OpERaTIOn         cOmpOnEnTS

           specifically designed to monitor and operate the       The automatic intermit-    Motors An electric motor and
                                                                  tent mode is adjustable by   gear box are furnished as part
           backwash cleaning system of Eaton Automatic            setting the timer in the panel   of the strainer. The standard
                                                                  that controls the frequency of   TEFC motor is 120V/220V,
           Strainers. Simple to operate, reliable, and easily     backwashing and the “open”   Single phase 60 Hz, or
           maintained. The design allows field adjustments        time of the backwash valve.   230V/460V Three Phase 60 Hz,
                                                                                             at customer option. Other
                                                                  Field adjustments should be
           to suit the demands of the service conditions,         made to suit the application.    motors are available.
                                                                  A differential pressure switch
           ensuring effective cleaning with a minimum use         to initiate backwashing under   Differential Pressure
                                                                  high load conditions also can   Switch A diaphragm-type
           of backwash fluid.                                     be adjusted.               differential pressure switch is a
                                                                                             standard component in all
                                                                  The continuous             Control Systems. It compen-
           STandaRd cOnTROL SySTEm FEaTuRES                       backwashing mode is        sates for sudden high pressure
                                                                  recommended where the      loading by overriding the time
           ACS-1 This system features   ACS-2 This system has all    backwashing fluid can be   cycle and initiating back-
           a NEMA 4 rated (water and   of the features of the ACS-1   recycled to its source or    washing. The differential
           dust tight) panel box complete   and includes a motor starter in   when very high solid loadings   pressure setting as well as a
           with adjustable timer, differen-  addition to the other standard   are encountered.  delay time setting can be
           tial pressure override, 10 amp   equipment.                                       adjusted. Two psid above the
           control relay for backwash                             In both the automatic intermit-  clean reading is the differential
           valve activation, display lights   ACS-3 This system has    tent and continuous back-  setting recommended. A
           to indicate Power On,      all of the features of the    washing modes the backwash   delay timer will continue the
           Backwash Valve Open, and   ASC-2 system and includes    arm continuously rotates at a   cleaning to customer’s
           High Differential Pressure. A   a 460V/120V step down    low 2-4 RPM.             requirement. The time delay
           selector switch is also    transformer.                                           can be adjusted from 0.6
           included to manually control                                                      seconds to 24 hours,
           the backwash valve functions   Optional designs to meet                           depending on system’s needs.
           of Off-On-Auto. The panel also   specific requirements with
           has contact terminals for a   special wiring arrangements,                        Backwash Valve Electrically
           motor starter and an external   panel boxes (NEMA 7, 9),                          actuated (115 VAC/60 Hz) ball
           alarm connection. The panel   control valves, and air actua-                      valves are also standard in the
           requires 110 VAC input, UL   tion among others, can be                            Control Systems. Materials of
           approval is available as an   furnished.                                          construction are suitable for
           option. The panel has a differ-                                                   water service. Other materials,
           ential pressure switch and an                                                     valve types and pneumatic
           electrically actuated ball valve                                                  actuation are optional.
           that controls the backwash
           function.                                                                         backwash valve Sizes
                                                                                              Strainer Size   Valve Size
                                                                                             2”, 3”, 4”           1”
                                                                                                                 1
                                                                                             6”, 8”             1  ⁄ 2 ”
                                                                                             10”, 12”, 14”, 16”   2”
                                                                                             18”, 20”, 24”, 30”   3”
                                                                                             36”                  6”
                                                                                             48”, 60”             8”
   6   7   8   9   10   11   12   13   14