Page 2 - Parker - Parker ProBond competitive advantage filter cartridge evaluations for industrial coatings and applications
P. 2

™
               ProBond  Performance



               Test Protocol                    Results
               Competitive cartridges, rated 5,
                                                                            Size at                  Size at
               10, 25, 50, and 75 micron nominal,   Published  Competitor DHC         Parker   DHC
               were tested per ASTM F-795-88      Rating    Product   (gm)   90%     ProBond   (gm)   90%
                                                                           Removal                  Removal
               Single Pass Test Method using
               standard SAE Test Dust in water at   5          A       91    12μm    PRO5-9     80    8μm
               a fl ow rate of 3.5 gpm per 10-inch   10        B      115    13μm    PRO10-9   182    12μm
               cartridge to a terminal pressure    25          C      178    18μm    PRO25-9   188    22μm
               drop of 30 psid. Dirt-holding       50          D      223    26μm    PRO50-9   219    38μm
               capacity (DHC) data, defi ned as
                                                   75          E      373    35μm    PRO75-9   358    80μm
               the weight of contaminant added
               to reach terminal pressure drop,
               was then compared to Parker Pro-             Competitor Product      Parker ProBond
                                                Published
               Bond™ cartridges. Particle removal   Rating  Turbidity Effi ciency %  Turbidity Effi ciency %
               effi  ciency was determined using           Initial  Middle  End  Initial  Middle  End
               a Coulter Multisizer II automatic    5       60      94     97      84     87      88
               particle counter. Th roughout        10      52      90     90      47     71      78
               the test inlet and outlet turbidity
                                                    25      49      97     97      34     78      78
               was measured with on-line Hach
                                                    50      67      92     93      37     71      74
               Model Ratio 2000 D turbidimeters.
                                                    75      31      78     82      33     40      44
                CONCLUSIONS

                1.  In comparing dirt-holding       customer fl exibility to make   fi ber dust fell off  the fi lters
                    capacities of competitors’      required adjustments in their   because of the short fi bers
                    cartridges, performance is      specifi c application.          and machined surface. Such
                    comparable. However, based                                      dust can easily contaminate
                    on fi eld experience in viscous   3. Th  e turbidity data shows that   fi ltered fl uids and cause
                    fl uids ProBond provides        the competitors’ cartridges     rejects. Th  e ProBond spiral
                    extended service life because   act as “clarifying” fi lters,   wrapped cartridges were
                    large particles are captured    i.e. effi  ciency improves      much cleaner.
                    in the coarse outer layer,      steadily throughout the life
                    protecting the inner layer      cycle. ProBond cartridges   5.  Because ProBond cartridges
                    from plugging prematurely.      act as “classifying” fi lters,   are made with prime acrylic
                                                    i.e. effi  ciency remains       and polyester fi bers, they
                2. Th  e competitors’ products      relatively constant during      are certifi ed silicone-free.
                    show little effi  ciency        fi ltration. Classifying fi lters   Th  e competitors’ cartridges
                    diff erentiation between 5      are preferred in most coating   could not be certifi ed
                    and 10 micron ratings. In       applications because            silicone-free because the
                    addition, their product at 25,   desirable particles, such as   source cannot be traced to a
                    50 and 75 microns refl ects     pigments, are allowed to        fi ber producer. Filters used
                    minimal performance             pass the fi lter while large    in the coatings industry
                    variations at 90% removal       agglomerated particles are      must be silicone-free
                    as compared to ProBond.         retained.                       to avoid changes to the
                    ProBond cartridges are                                          adhesion properties and
                    distinctly diff erent at all   4.  While handling the           eliminate blemishes in the
                    rating levels giving the        competitors’ cartridges,        coated surface.


               © 2010 Parker Hannifi n Corporation                                                  TAP-019  Rev. B
               domnick hunter Process Filtration - North America
   1   2