Page 21 - Parker - Coils and Electronics
P. 21
Catalog HY15-3502/US Proportional Valve Controller
Technical Information Series XPRO902d, 932d, 904d, 934d
CV
Dimensions Millimeters (Inches) Ordering Information
34.0 68.0 Check Valves
(1.34) (2.68) XPRO
SH
Controller Maximum
40.0 Current
(1.57) Shuttle Valves
Code Maximum Current
902d 1.6A
LM
932d 2.6A
904d 1.0A Load/Motor
934d 1.4A Controls
Setting for standard:
Dither frequency: 110 HZ
FC
Flow Controls
Connection Details
PC
XPRO902d and XPRO932d XPRO904d and XPRO934d
Pressure Controls
10K Potentiometer 10K Potentiometer
Red: +12V Red: +24V
Yellow: +8V ref Yellow: +15V ref LE
Logic Elements
Green: Command Green: Command
DC
Directional Controls
Blue: 0V Blue: 0V Supply Blue: 0V Blue: 0V Supply
MV
From PLC From PLC
Red: +12V Red: +24V
Manual Valves
Yellow: +8V ref (not used) Yellow: +15V ref (not used)
SV
0-10V Green: Command 0-10V Green: Command
Solenoid Valves
0V 0V
Blue: 0V Blue: 0V Supply Blue: 0V Blue: 0V Supply
PV
Proportional Valves
Controller / Coil Combination
CE
Controller Controller
Coil XPRO 902d XPRO 932d Coil XPRO 904d XPRO 934d Coils & Electronics
CCS012D X CCS024D X
CCP012D X CCP024D X BC
CAS012D X CAS024D X
Bodies & Cavities
CAP012D X CAP024D X
TD
Technical Data
CE20 Parker Hannifin Corporation
Hydraulic Cartridge Systems