Page 20 - Linde - HPR-02 Self regulating pump for open loop operation
P. 20
Controllers.
The modular controller unit enables a wide range of functional system requirements to be met. In all controller unit versions, the
regulating functions are integrated in a housing in order to ensure direct signal transfer without delays and with maximum com-
pactness. All controllers equipped with load sensing function are fully compatible with the Linde Synchron Control System (see
section <<Linde LSC-System>>).
Technical data
Swashplate position
Type of regulation Additional function Name
feedback
With pressure cut-off without LP
with ∆pLS override without E1L/H1L
Load Sensing
with hyperbolic power limiting with TL2
electro-proportional flow limitation and with LEP
pressure cut-off
electro proportional flow setting, power
Control with ETP
limitation and pressure cut-off
Controllers without swashplate position feedback.
Mounting on the port plate housing
LP-controller H1L-controller E1L-controller
Controllers with swashplate position feedback.
Mounting on the pump housing
TL2-controller LEP-controller ETP-controller
20