Page 89 - Viledon - Air and Liquid Filtration
P. 89
Gas phase filters
Systems | ChemControl Recirculation Units
Application Viledon CRU: The ‘recirculating air filtration’ system
®
Many industrial processes generate contaminant gases that can cause corrosion. The Viledon ChemControl Recirculation Unit (CRU) is a system fully based on
®
Even minor damage to electronic components can have serious consequences, recirculated air filtration. This makes it an ideal addition for rooms that are
e. g. fault signals, unplanned downtime, high repair costs. The Viledon supplied with filtered air and maintained at positive pressure using a Viledon
®
®
®
ChemControl Recirculation Unit (CRU) and the Viledon ChemControl ChemControl Deep-Bed Pressurization Unit (CDBPU).
Recirculation Pressurization Unit (CRPU) are multi-stage filtration systems that
reliably provide complete protection against corrosion. Viledon CRPU: The ‘outside air + recirculating air filtration’ system for
®
overpressure generation
In both systems, Viledon Compact pocket filters are used in the pre-filtration
®
®
stage. Positioned before and after the fan, the Viledon ChemControl Modules Using an admixture of outside air, the Viledon ChemControl Recirculation
®
with pellets eliminate harmful gases. Viledon MaxiPleat cassette filters ensure Pressurization Unit (CRPU) can maintain a slight positive pressure within the room
®
secure fine filtration. Integrated pressure gauges allow for reliable monitoring to be protected. At moderate concentrations of corrosive gases, the Viledon
®
®
onsite. CRPU can be operated without the use of a Viledon ChemControl Deep-Bed
Pressurization Unit.
Delivery notes
Please consult your local Viledon ® partner for further information.
Viledon CRU*
®
Article Nominal Dimensions Weight Number of Number of Number of fine Power consumption
volume flow (H × W × D) [kg] modules per stage pre-filters filters average
3
[m / h] [mm] [kW]
1800 DW 1,800 2,600 × 750 × 750 550 4 1 1 0.8
1800 DW stainless steel** 1,800 2,600 × 750 × 750 580 4 1 1 0.8
3600 DW 3,600 2,600 × 1,500 × 750 650 8 2 2 1.3
3600 DW stainless steel** 3,600 2,600 × 1,500 × 750 680 8 2 2 1.3
Viledon CRPU*
®
Article Nominal Dimensions Weight Number of Number of Number of fine Power consumption
volume flow (H × W × D) [kg] modules per stage pre-filters filters average
[kW]
[mm]
[m / h]
3
Subject to technical changes. 1800 DW 1,800 2,600 × 750 × 750 560 4 4 8 8 1 1 2 2 1 1 2 2 0.8 89
1800 DW stainless steel**
0.8
590
1,800
2,600 × 750 × 750
3600 DW
3,600
2,600 × 1,500 × 750
660
1.3
1.3
2,600 × 1,500 × 750
3,600
690
3600 DW stainless steel**
* Standard casing: double wall casing ensuring low noise, manufactured using alumina corners and panels with plastisol coating.
** Stainless steel casing also available as single wall (SW) model.