Page 37 - Critical Control flipbook_Neat
P. 37

Contact with Hot Meal











           1    What is the name of the       2    What are its specific objectives related to the Priority Unwanted
                                                   Event (PUE)?
                critical control for Contact
                with Hot Meal?
          Access Control                     Minimize the number of people exposed to hot meal hazards


           3    What are the critical         4    What are the activities       5    What can be sampled from
                control performance
                                                   within the management
                                                                                      the set of activities for
                requirements to meet the           systems that support               verification, providing a
                objectives?                        having the critical control        clear image of the critical
                                                   able to do what is required?       control status?
          Only workers performing daily tasks   Maintain a log of entry/exit of personnel   Records of entry/exit of personnel in the
          in the hazardous areas are formally   in the areas                    area
          authorized
          Non authorized workers shall not be able
          to access the areas at risk without formal
          authorization for each entry
          Hot meal hazardous areas are physically   Inspection and maintenance of access   Number of access points missing
          blocked for access                 controls                           physical access control
          Visible and audible alarms in the   PM´s for inspection and testing of visible   Verification of completion of PM´s
          preheater tower warn of unsafe     and audible alarms are set up in the   (inspection and tests) as well as ad-hoc
          conditions (either manually triggered   Computerized Maintenance Management   testing in the field
          and/or by interlocked instrumentation)  System

          Warning signage at entry points of   Warning signage explaining risks, access   Number of access points missing
          hazardous areas                    control mechanism, nature of visible and   warning signage
                                             audible alarms and PPE requirements

          All openings into preheater tower   Inspection and maintenance of all closing   Number of openings to preheater tower
          (hatches, portholes, poking holes etc.)   devices                     that can be opened without a tool
          require a tool to open


           6    What is the target performance for critical     7    What is the critical control performance
                control?
                                                                     trigger for shutdown, critical control review or
                                                                     investigation?
          Unauthorized personnel cannot access the areas at risk  Unauthorized personnel access or able to access the hotmeal
          Visual and audible alarms work upon manual triggering (e.g.   hazardous areas
          by CCR Operator or preheater cleaning crew, etc...) or upon   Audible and visible alarms not functioning
          achieving alarm values from instrumentation



















          Creation date: 01/2021 • The latest and only controlled version of this document is available on the HSE intranet.
          © 2021 Holcim - For internal use only
   32   33   34   35   36   37   38   39   40   41   42