Page 10 - DSL KZJ
P. 10
Location of additional Terminal Board (TB) in ECC3 panel
2. Fabrication of Wiper motor test stand
Earlier the overhauled wiper motor was checked with pneumatic
pressure on work bench and was fitted on loco. Problems were noticed
after fitment on loco along with wiper blade. To avoid re-work, a test
stand is developed to test the working of overhauled / new wiper motor
and also test the wiping efficiency of wiper blades (to check the wiping
angle of 70 deg) along with pressing of wiper over look out glass.
Water spray
arrangement
Wiper
blade
Wiper
motor
Test Stand for Wiper Motor and Wiper Blade