Page 8 - DSL KZJ
P. 8

FPM Stand-by

                           switch







                        FPM Stand-by
                            inverter






                   4.  INNOVATIONS



                                  1.  Provision of additional Terminal Board TB83A
                                       in ECC3 compartment of HHP Locos
               Loco  No  –  70650  has  failed  on  05-07-21  due  to  LR  dropping  after  4
                                                                                                              th
               notch. On investigation, it is found that Terminal Board no – TB83A is in
               burnt  condition  in  ECC3  compartment  due  to  FPM  wires  SRA&  SRA1,
               SFN&SFN1 are burnt in TB.
               The loco is equipped with Siemens Ac-Ac system. In Siemens locos, the

               TB83A  is  unable  to  withstand  the  continuous  FPM  current  of  9A  and
               resulting in TB getting burnt.
               Hence, a modification is carried out by providing additional TB (of Alco
               loco)  in  ECC3  compartment.  The  FPM  wires  of  SRA/SRA1  &  SFN/SFN1
               are removed from the existing TB83A and connected to the TB which is
               provided additionally. This will result in elimination of burning of existing

               TB (due to removal of FPM wires).

                                            View of ECC#3 Compartment