Page 83 - Icon Ridge Sanitary-Heating-Air Catalog
P. 83

Building Services

          Insulation for Ball Valves


         The clever insulation for ball valves for virtually all common
         European ball valve types
         • Made of closed-cell foamed polyethylene with additional firm mesh
           effect made of PE
         • Easy and rapid assembly: shift, fold and securely closed by means of
           closing clips
         • Equipped with universal recess
         • Warm remains warm – cold remains cold!
         • Avoids formation of condensation water
         • A non-insulated valve emits as much heat or absorbs as much
           heat as several meters of tube
         • Offers a rapid and easy mountable closing of gaps in professionally
           installed and exemplarily insulated cold water bearing drinking water
           pipes, hot water bearing service water pipes, heating pipes as well
           as industrial piping networks
         • No time consuming cutting of isolation mats, no expensive individual
           solutions or even brilliant valves which would reduce the overall
           effect of costly mounted pipe insulations and which would impair the
           optics of the system
         Fields of application:
         • DIN 1988 TRWI: Protection against heating up, formation of
           condensation water and sound transmission of drinking water pipes
         • EnEV Annex 5: Requirements to limit the heat emission of heat
           distribution and heat water pipes as well as of fittings  Technical Data
                                                               Thermal conduct./calcul. value: at 10°C ISO 2581 W/mk 0,035
          Article No.  Article Description             QTY                              at 40°C ISO 2581 W/mk 0,040
          8729 2 15  INSULATION BALL VALVE 1/2"DN15    e 10    Noise insulation:        DIN 4109 dB
          8729 2 20  INSULATION BALL VALVE 3/4"DN20    e 10    Fire protection:         Ü-No Z-23.14-1141 PE foam
          8729 2 25  INSULATION BALL VALVE 1"DN25      e 10                             is quality controlled DIN 4102 B1
          8729 2 32  INSULAT.BALL VALVE 1 1/4"DN32     e 10    Water vapor permeability:  ISO 1663 g/m² 1,1 (5,0 mm)
          8729 2 40  INSULAT.BALL VALVE 1 1/2"DN40      e 5    Water vapor diffusion factor:  µ > 4000
          8729 2 50  INSULATION BALL VALVE 2"DN50        1     Use temperature:         DIN 1988 -80°C to +100°C
          Included in delivery:
          • 2x Closing clips
          • 1x Valve insulation


          Insulation for AP Water Meters

          The insulations for water meters are available with the connection
          diameters ½” and ¾” for all products according to DIN
          • Is an accurately fitting solution for water meters of the manufacturers
           Allmess, Rossweiner, WasserGeräte GmbH, Conter Caracioni and
           Sensus Metering Systems
          • Made of closed-cell foamed polyethylene with additional firm mesh
           effect made of PE
          • Easy and rapid assembly: shift, fold and securely closed by means of
           locking clips
          • Equipped with universal recess
          • Warm remains warm – cold remains cold!
          • Avoids formation of condensation water
          • A non-insulated valve emits as much heat or absorbs as much
           heat as several meters of tube
          Fields of application:
          • DIN 1988 TRWI: Protection against heating up, formation of
           condensation water and sound transmission of drinking water pipes
          • EnEV Annex 5: Requirements to limit the heat emission of heat  Technical Data
           distribution and heat water pipes as well as of fittings  Thermal conduct./calcul. value: at 0°C ISO 2581 W/mk 0,035
                                                                                        at 40°C ISO 2581 W/mk 0,040
                                                               Noise insulation:        DIN 4109 dB
                                                               Fire protection:         Ü-No Z-23.14-1141 PE foam
                                                                                        is quality controlled DIN 4102 B1
                                                               Water vapor permeability:  ISO 1663 g/m² 1,1 (5,0 mm)
          Article No.  Article Description             QTY
                                                               Water vapor diffusion factor:  µ > 4000
          8729 3 15  AP WATER MET.INSULAT.1/2"DN15     e 10
                                                               Use temperature:         DIN 1988 -80°C to +100°C
          8729 3 20  AP WATER MET.INSULAT.3/4"DN20     e 10
          Included in delivery:
          • 2x Closing clips
          • 1x Valve insulation




     Technical data subject to change.
     Availability subject to country specific rules and regulations.   www.iconridge.com   Source: Theo Förch GmbH & Co. KG           83