Page 144 - 2022FittingsCatalog
P. 144

TEMPERATURE GAUGES

           This temperature gauge is commonly used to monitor water tem-  Our Bi-Metal Thermometers are manufactured in accordance with ASME
           perature in winter where freezing will cause problems.  The 2.5"   B.40.3 standards for maximum accuracy and quick response. Made from
           long rod is back mounted and can be inserted into the water flow   Type 304 Stainless Steel, these back-mounted thermometers feature
           via a tee junction or 1⁄2" NPT pipe plug. The face is 3" diameter.  food grade, shatter-proof glass windows and are available with either
                                                                21⁄2" or 4" long stems. Choose from temperature ranges of -20°C to
                                                                120°C or from 10°C to 260°C. To prevent damage to the thermometer
                                                                and facilitate easy removal from processing, the use of a thermowell
                                                                is recommended.











                Temperature Range           Rod
        Part No.  °C     °F         Thread   Length
        TG-4070  -40°-70°  -40°-160°  1 ⁄2"NPT  2.5"                      Temperature Range            Rod
                                                              Part No.    °C      °F        Thread     Length
                                                              TG-10260-2.5  10°-260°  50°-500°  1 ⁄2" NPT  2.5"
                                                              TG-10260-4  10°-260°  50°-500°  1 ⁄2" NPT  4"
                                                              TG-20120-2.5  -20°-120°  -4°-248°  1 ⁄2" NPT  2.5"
                                                              TG-20120-4  -20°-120°  -4°-248°  1 ⁄2" NPT  4"





                                                                Thermowells are recommended for use in food processing to both pro-
                                                                tect the thermometer from damage as well as enable removal of the
                                                                thermometer for replacement or repair without affecting processing.
                                                                We carry thermowells designed to accept either 2 1 ⁄2" or 4" stem ther-
                                                                mometers. They are manufactured from Type 316 Stainless Steel and
                                                                feature  3 ⁄4" Male Pipe (NPT) process connections for easy attachment
                                                                to our Compact Female Pipe Clamp Adapters. Instrument connections
                                                                are  1 ⁄2" Female Pipe (NPT).









                                                                        Process    Instrument  Stem   Insertion
                                                              Part No.  Connection  Connection  Length  Length

                                                              TG-TW-2.5  3 ⁄4" Male NPT  1 ⁄2" Female NPT  2.5"  1.25"
                                                              TG-TW-4.0  3 ⁄4" Male NPT  1 ⁄2" Female NPT  4.0"  2.50"