stations at the required speeds.” With
       exacting demands in terms of safety
       and reliability and the need to maintain
       hundreds of escalators any technical
       change has significant implications so
       the escalator engineers are meticulous
       in assessing any new optimisation
       opportunities.
         The reality is it’s an ongoing process
       of modernisation in an environment
       that  is  highly  resistant  to
       standardisation, because after all, the service life of   The motor windings can also serve as ‘braking
       an escalator is around 30 years. At any one time,   resistors’, converting energy into heat, but only to a
       multiple generations and models from different   limited extent and not continually. It would also be
       manufacturers are in use across the network, while   possible to supplement an inverter drive with an
       the individual spatial conditions are equally diverse.   additional regenerative unit, but this is not feasible
         Daniel Mayer, responsible for the electro   due to limited space in escalator control cabinets.
       technology of the escalators says, “In a nutshell,
       every system is unique”. MVG tackles this challenge  The solution
       by drawing on its own powers of innovation, with   Eventually a solution was found in the technology
       one example being the manufacturer-independent   that is still rarely used in low voltage applications, a
       escalator control system which they developed   matrix converter that combines the inverter and
       themselves. This means each escalator can be   regenerative unit in a single device. In the spring of
       maintained by in-house personnel, faults can be   2016 MVG tested the capability of the few market-
       rectified faster and costs for spare parts and   ready options available using their own simulator.
       conversions are minimised.           Among the specific escalator requirements was a
                                            flying start function to ensure synchronised start-up
       The benefits of inverter drives      after automatic deactivation and all electrical
       TMVG has been using inverter drives since before   components have to operate year round at outside
       the development of the new control system the   temperatures.
       benefits of which quickly became apparent over   Yaskawa’s newly developed U1000 was one of
       conventional drives in every day operation on   the units tested and as far as MVG were concerned,
       upward escalators. The inverter control enables   it ticked all the boxes. First introduced by Yaskawa
       variable start-up and stopping, which means not   in 2014 the U1000 matrix converter is a highly
       only more comfort for the users, but also protects   efficient, regenerative direct inverter for powering
       the mechanisms. However, as impressive these   induction and permanent magnet machines, with or
       benefits were, MVG had been searching for a   without speed sensors.
       suitable solution for downward escalators.    Today the range covers a wide power range from
         While many systems work with conventional   2.2 to 500kW and thanks to its innovative design is
       braking resistors, the resulting waste heat has to be   capable of direct regeneration and doesn’t require
       dissipated safely, not least for fire safety reasons.   any DC bus capacitors. No space is needed for an

                           February 2021 • INDUSTRIAL TECHNOLOGY EXTRA • p7