Page 48 - Green Builder Jan-Feb 2022 Issue
P. 48

FLOOR
                                                   PLAN
                                                               GARDEN
            Key Components

                                                                             BEDROOM
            ALTERNATIVE BUILDING SYSTEMS: M-Due (M2)
            structural insulated concrete panels (SIPs) at roof
            APPLIANCES: Jangada gas stove; recycling bins by                     BATH
            Curver and Sterilite
            BUILDING ENVELOPE: M-Due (M2) SIPs at roof;                                       OUTDOOR
            6-inch cavity concrete blocks at walls                                             DINING
            CABINETS, SHELVES, MILLWORK: Locally sourced                       KITCHEN
            from community cabinet maker; bathroom vanity by
            Garrido Bros. & Co.
            CAULKS AND SEALANTS: DAP Products                                    DINING
                                                                      ENTRY
            COUNTERTOPS: Formica plastic laminate
            DOORS AND HARDWARE: Air Master aluminum                  WATER
            operable Jalousie doors with integrated vandal          CISTERN                    PATIO
            resistant bars and low e-glass transoms; Toledo
            interior hardware
            ELECTRICAL: Schneider Electric Square D main
            distribution panel; HYDROMAXX Flex electric
            conduits; Hampton Bay ceiling fans and lights
                                                                               BEDROOM
            EXTERIOR FINISHES: Ecológica Carmelo Special
            Cement Plaster Mix
            FLOORING: Behr gray floor paint
            FURNITURE: Capri department stores, Puerto Rico
            INSULATION: 4-inch expanded polystyrene
            LANDSCAPING: Donation by Abruña & Musgrave,
            Architects                            Into this scenario stepped San Juan-  privacy to an interior side patio. This
            LIGHTING: EcoSmart LED interior bulbs, Feit Electric   based Abruña & Musgrave, Architects,   simple volume is peppered with oper-
            exterior bug lights, Dark Sky-rated Home Decorators   which responded to a call ffor a Puerto   able jalousie windows and low-e glass
            Collection exterior light fixtures   Rico architectural design competition to   transoms (the solar heat gain coeffi-
            PAINTS AND STAINS: Behr              help provide an affordable sustainable   cient [SHGC] is an impressive 0.40)
                                                 and resilient home to Hurricane Maria   for daylighting and natural ventilation.
            PLUMBING/PLUMBING FIXTURES: Mediterraneo
            shower console; Elkay kitchen sink; Glacier Bay 1.28   victims. The result was Mi Casa Resis-  Walls are built with 6-inch concrete
            gallons per flush (GPF) toilet, Nature’s Head   tente (My Resilient House), a prototype,   masonry units (CMUs) and reinforced
            composting toilet                    highly sustainable tiny home (and Green   concrete columns.  R-20 structural
                                                 Builder’s 2022 Green Home of the Year   insulated concrete roof panels mitigate
            RENEWABLE ENERGY SYSTEMS (SOLAR, WIND,
            ETC.): KiloVault RES-Q portable power system.  in the Best Right-Sized Shelter category).  solar heat influx and reduce CO2 emis-
                                                  This is a 528-square-foot two-bed-  sions through less use of cement. Four
            ROOF: BULL-BOND PRO-ONE cool roof coating
                                                 room (expandable to three) resilient   jalousie doors that connect the interior
            VENTILATION: Air Master natural ventilation with   dwelling on a 1,715-square-foot lot in   spaces with the 372-square-foot side
            operable aluminum jalousie doors and windows
                                                 Puerto Rico’s Caño Martín Piña area.   garden/patio and its pergola shape
            WATER HEATING: Stiebel Eltron inline electric water   “Passive green, energy conservation   the emblematic space that enhances
            heater                               and resiliency strategies are incorpo-  the tropical climate and informal life
            WATER MANAGEMENT (INDOOR/OUTDOOR):   rated throughout the design,” notes   style, Abruña notes.
            Columnar 200 gallon polypropylene rainwater   Fernando Abruña, the project’s archi-
            harvesting, gravity-fed cistern; 500 gallon rooftop   tect and co-owner of Abruña & Mus-   A “JUST IN CASE” CLAUSE
            mounted polypropylene utility fed cistern
                                                 grave, Architects, with project designer   After what happened to Puerto Rico
            WINDOWS, SKYLIGHTS, PATIO DOORS: Air Master   Margaret Musgrave.      during and after Hurricane Maria,
            aluminum operable jalousie doors with integrated   A  64-square-foot  balcony  and  a   Abruña & Musgrave, Architects set up
            vandal resistant bars and low e-glass transoms; low-e   graveled parking area are provided. A   Mi Casa Resistente with numerous
            glass transoms
                                                 42-foot-by-12-foot volume with a front   backup elements in case such an event
                                                 facade that extends to the side adds   occurs again.


               46   GREEN BUILDER January/February 2022                                       www.greenbuildermedia.com
   43   44   45   46   47   48   49   50   51   52   53