Page 23 - Green Builder Magazine Jan-Feb 2018 Issue
P. 23

Frame failure. If fasteners are
                                                                                                          inadequate, sliding glass doors
                                                                                                          can be blown completely out of
                                                                                                          their jambs.

























               CREDIT: FEMA





                           Structural design that did                             LAZINGS IN LARGER WINDOWS have been known to blow
                     3                                                            completely out of their frames, even if the glazing is laminated
                           not account for unprotected                            or otherwise protected. This negates the advantages of impact
                                                                                  glass or applied impact window films. However, the solution
                           glazing, leading to structural               G may be simple: Increase the number of fasteners holding the
                           failures due to increased                     frame in place. It’s too easy to cut corners and apply fewer fasteners than
                                                                         recommended by the manufacturer.
                           internal pressures.






                     4     Corrosion of anchors or connectors that attach the building to the
                           foundations or tie structural elements together resulted in structural

                           collapse in some instances.


                            GAIN, THIS IS a relatively easy issue to address. Assume
                            the worst, when it comes to corrosion. Keep in mind that
                            most concrete at the top of a concrete slab or foundation   Made to last. Stainless concrete anchors like this one from Simpson
                            wall can only dry to about the same level of moisture   Strong-Tie mitigate the problem of corrosion at a home’s base.
                   A as the ambient air. So in the Southeast, it will remain                               Danger zone. Rusty anchor
                   wetter than out west. Also, if the concrete was installed without                       bolts of mild steel are
                   vapor barriers underneath it, its moisture level will follow the ups                    almost inevitable in damp
                   and downs of the adjacent soil. Metal fasteners will be constantly                      soils, and frequently fail
                   exposed.                                                                                under stress.
                     Fortunately, corrosion-resistant versions of foundation anchors are
                   now widely available. For example, Simpson sells 25 stainless steel,
                   half-inch concrete anchors (5-1/2-inch length) for about $70. That’s
                   about twice the cost of galvanized versions, but your clients will
                   probably understand why it’s important. Be sure to have an engineer
                   recommend the best size/thickness.

                   www.greenbuildermedia.com                                                 January/February 2018 GREEN BUILDER  21




          18-25 GB 0118 NR-Next Big One.indd   21                                                                              12/14/17   4:10 PM