Foam Plastic, Attic and Crawl Spaces
























        Figures are excerpted from the 2015 International Residential Code Commentary, Copyright (C) 2015 International Code Council, Inc., www.iccsafe.org. All rights reserved. Excerpts reprinted with permission.














            Figure R408.4


                       Foam Plastic Spray Applied                          Referenced Section R408.4
                          to Sill Plate and Header                         is simply the detailed
                                                                           requirement for the access

                                                                           for “under-floor spaces.”

                                                                           Referenced Section 316.4
                                                                           details the “approved

                                                                           thermal barrier” to be “not
                                                                           less than ½-inch gypsum
                                                                                    23
                                                                                      32
                                                                           board,  ⁄ -inch wood
                                                                           structural panel or a material

                                                                           that is tested in accordance
                                                                           with and meets the
                                                                           acceptance criteria of both
                                                                           the Temperature

                                                                           Transmission Fire Test and
                                                                           the Integrity Fire Test of
                                                                           NFPA 275.”