Page 33 - 12558 Drexler Builder Binder.pdf
P. 33

as necessary to bring the variance within   from the line and clear the line when
                                                               the standard.                  necessary.
                              14.2 A drip pan and drain line shall be installed   If a drip pan and drain line fails to meet the   The Owner shall periodically check for
                                  under a horizontal air handler as per the   standard, the Builder shall take such action   the free flow of condensate (water)
                                  Code.                        as necessary to bring the variance within   from the line and clear the line when
                                                               the standard.                  necessary.
                              14.3 Insulation shall completely encase the   If the refrigerant line insulation fails to meet   The Owner shall ensure that insulation
                                  refrigerant line according to Code.  the standard, the Builder shall take such   on the refrigerant line is not damaged
                                                               action as necessary to bring the variance   or cut due to Home maintenance or
                                                               within the standard.           landscape work.
                              14.4 An exterior compressor unit shall be   If an exterior compressor unit pad or   The Owner shall ensure that
                                  installed on a stable pad that supports the   support fails to meet the standard, the   settlement of the exterior compressor
                                  unit and is no more than one inch out of   Builder shall take such action as necessary   unit pad does not occur due to Home
                                  level.  The bottom of the exterior   to bring the variance within the standard.  maintenance, landscape work or
                                  compressor unit support shall not be                        excessive water from irrigation.
                                  below ground level.
        VENTING               14.5 An appliance shall be vented according to   If an appliance is not vented per the   None.
                                  the manufacturer's specifications.    standard, the Builder shall take such action
                                                               as necessary to bring the variance within
                                                               the standard.
                              14.6 Back draft dampers shall be installed and   If back draft dampers fail to meet the   None.
                                  function according to the manufacturer's   standard, the Builder shall take such action
                                  specifications.              as necessary to bring the variance within
                                                               the standard.
        DUCTWORK              14.7 Ductwork shall not make excessive noise.  If the ductwork fails to meet the standard,   The flow of air, including its velocity, or
                                                               the Builder shall take such action as   the expansion of ductwork from
                                                               necessary to bring the variance within the   heating and cooling may cause
                                                               standard.                      "ticking" or "crackling" sounds.  The
                                                                                              Owner shall not place any object on
                                                                                              the ductwork.
                                                 15.  ELECTRICAL SYSTEMS & FIXTURES
        ELECTRICAL SYSTEMS &   15.1 Excessive air infiltration shall not occur   If electrical system components or fixtures   Surfaces altered incident to any repair
        FIXTURES                  around electrical system components or   fail to meet the standard, the Builder shall   will be finished or touched up to match
                                  fixtures.                    take such action as necessary to bring the   the surrounding area as closely as
                                                               variance within the standard.  practical.
                              15.2 A fixture or trim plate shall not be chipped,   If a fixture or trim plate fails to meet the   Surfaces altered incident to any repair
                                  cracked, dented or scratched due to   standard, the Builder shall take such action   will be finished or touched up to match
                                  construction activities.     as necessary to bring the variance within   the surrounding area as closely as
                                                               the standard.                  practical.
                              15.3 A fixture or trim plate finish shall not be   If a fixture or trim fails to meet the standard,   Surfaces altered incident to any repair
                                  tarnished, blemished or stained due to   the Builder shall take such action as   will be finished or touched up to match
                                  construction activities.     necessary to bring the variance within the   the surrounding area as closely as
                                                               standard.                      practical.
                              15.4 A fixture, electrical box or trim plate shall   If a fixture, electrical box or trim plate fails to   Surfaces altered incident to any repair
                                  be installed per the Code and shall be   meet the standard, the Builder shall take   will be finished or touched up to match
                                  plumb and level.             such action as necessary to bring the   the surrounding area as closely as
                                                               variance within the standard.  practical.
                              15.5 Fixtures, such as lights, fans and   If a fixture, light, fan or appliance fails to   None.
                                  appliances shall operate properly when   meet the standard, the Builder shall take
                                  installed per the manufacturer's   such action as necessary to bring the
                                  specifications.  The         variance within the standard.
                              15.6 A smoke detector shall operate according   If a smoke detector fails to meet the   None.
                                  to the manufacturer's specifications and   standard, the Builder shall take such action
                                  shall be installed per the Code.    as necessary to bring the variance within
                                                               the standard.
                              15.7 An exhaust fan shall operate within the   If an exhaust fan fails to meet the standard,   None.
                                  manufacturer's specified noise level.    the Builder shall take such action as
                                                               necessary to bring the variance within the
                                                               standard.
                                                        16.  INTERIOR TRIM
        INTERIOR TRIM         16.1 An interior trim joint separation shall not   If an interior trim joint fails to meet the   Surfaces altered incident to any repair
                                  equal or exceeds 1/8 of an inch in width or   standard, the Builder shall take such action   will be finished or touched up to match
                                  shall not separate from adjacent surfaces   as necessary to bring the variance within   the surrounding area as closely as
                                  equal to or in excess of 1/8 inch and all   the standard.   practical.
                                  joints shall be caulked or puttied.
                              16.2 The interior trim shall not have surface   If the interior trim fails to meet the standard,   Surfaces altered incident to any repair
                                  damage, such as scratches, chips, dents,   the Builder shall take such action as   will be finished or touched up to match
                                  gouges, splits, cracks, warping or cupping   necessary to bring the variance within the   the surrounding area as closely as
                                  that is visible from a distance of six feet or   standard.  practical.
                                  more in normal light due to construction
                                  activities.

                                                            PAGE 16