Page 38 - PC 101 Interactive practical book
P. 38

MANSOURA NATIONAL UNIVERSIY
         PHARM D- CLINICAL PHARMACY                        LEVEL I                        PHARM. ANAL. CHEM. I (PC 101)



                                 C Ch ho oi ic ce e   o of f   A Ac ci id d- -B Ba as se e   I In nd di ic ca at to or rs s



             For accurate titrimetric method, the indicator should be selected so as to

          make the titration error small as possible. To achieve that the pH-range of the


          indicator  should  fall  in  the vertical part  of  the  titration  curve  (i.e.  the  part


          marked by sharp change of pH) because the equivalence point is located in this


          part  so  the  difference  between  (the  equivalence  point)  and  (the  end  point

          indicated by the selected indicator) will be small as possible.


          Example:

          Titration of NaOH with standard HCl using M.O. or ph.ph. indicator:



                   NaOH + HCl  NaCl + H 2O                       pH
                                            (pH = 7)



          The      calculated        equivalence         point                                     pH range of ph.ph.

          corresponds to pH=7.
                                                                    7

          But  since  the  vertical  part  of  this

          titration curve ranges from about 3.5 to                                      pH range of M.O.

          10.5  so  either  M.O. (3 – 4.5)  or

          ph.ph. (8.5 – 10)  can  be  used  as                                           M.O. End   mls  added of
                                                                             Equivalence
                                                                                          Point
                                                                                Point



                                                                                (Theoretical)       (Experimental)   standard HCl
          indicator for this titration.                                          Titration Error
                                                                                  (very small)
















          38 | P a g e