Page 194 - McD_6118-AEW-XX-XX-NBS-A-001_Neat
P. 194

H31 Metal profiled/ flat sheet cladding/ covering

          TYPES OF CLADDING SYSTEM

120 METALgenerally
      • Support structure: site specific; generallygalvanized steel Zed purlins.
          - Bearing width (minimum): material specific.
          - Pitch: site specific.
      • External sheets: Steel to BS EN 508-1.
          - Manufacturer: Contractor's choice.
             Product reference: Contractor's choice.
          - Material: Steel to BS EN 10346, grade S220GD+Z275.
          - Thickness (nominal): min 0.7 mm.
          - Finish side 1 (outer): site specific.
             Colour: site specific.
          - Finish side 2 (inner): site specific.
             Colour: site specific.
          - Additional requirements: None.
      • Accessories: As required to complete installation.
      • Primary cladding/ covering sheet fasteners: Self drilling and tapping stainless steel
          stand off screws with assembled stainless steel EPDM elastomer faced sealing
          washer and plastics cap colour.
          - Fastener profile location: Crown.
          - Number of fasteners per sheet width:
             Eaves and end laps: site specific.
             Intermediate supports: site specific.
      • End laps size (minimum): as manufacturers recomendations.
      • Sealing laps:
          - End laps: Two rows of partially cross linked butyl rubber sealant tape.
          - Side laps: One row of partially cross linked butyl rubber sealant tape.
      • Stitching laps:
          - End laps: Self drilling stainless steel screws with assembled stainless steel EPDM
             elastomer faced sealing washer and plastics cap colour.
          - Side laps: Self drilling stainless steel screws with assembled stainless steel EPDM
             elastomer faced sealing washer and plastics cap colour.
      • Spacers: site specific.
          - Fasteners: site specific.
      • Breather membrane: site specific.
      • Thermal insulation: site specific.
      • Vapour control layer: site specific.
      • Acoustic insulation: site specific.
      • Lining sheets: site specific.
      • Additional requirements: site specific.

          FIXING CLADDING/ COVERING

215 PAINTING STRUCTURE
      • Sequence: Paint outer surface of supporting structure before fixing cladding/
          covering.