Page 198 - McD_6118-AEW-XX-XX-NBS-A-001_Neat
P. 198

H42 Precast concrete panel cladding/ features

            TYPES OF CLADDING/ FEATURES

  110 PRECASTgenerally
        • Support structure: Steel frame.
        • Panel type: Sandwich.
        • Panel finish:
             - Matching sample: sample to be agreed.
             - Profile: site specific.
        • Thermal insulation: site specific.
        • Fixing: site specific.
        • Panel joints: site specific.
        • Accessories/ Features/ Incorporated components: site specific.

            GENERAL REQUIREMENTS/ PREPARATORY WORK

  210 DESIGN
        • Cladding: Complete detailed design.
             - Standard: To BS 8297.
        • Related works: Coordinate in detail design.

  222 FABRICATION SAMPLES
        • General: During detailed design work, submit samples of to be agreed.
             - Obtain approval of appearance before proceeding.

            DESIGN/PERFORMANCE REQUIREMENTS

  232 INTEGRITY OF CLADDING
        • Requirement: Determine sizes and thickness of panels, sizes number and location of
            fixings and handling fixings, incorporation of accessories and components to
            ensure cladding installation and panels will resist factored dead, imposed and
            design live loads and accommodate deflections, shrinkage, creep, handling and
            thermal movements without damage.
        • Wind loads: Calculate to BS 8297 Annex A appropriate to location and exposure
            and taking account of existing and known future adjacent structures.
             - Basic wind speed: as BS 8297 to suit site location.
             - Funnelling: to suit site constraints and adjacent buildings.
             - Terrain category: as BS 8297 to suit site location.
             - Topographical factor: as BS 8297 to suit site location.
        • Impact loads: Visible surfaces of cladding to meet the requirements of BS 8297
            clause 12.2.5.
        • Temporary imposed loads: site specific.

  236 THERMAL PROPERTIES
        • Thermal transmittance (U-value) of precast panel including joint: site specific.

RotF generic (intermediate) NBS 2014  6118-AEW-XX-XX-NBS-A-01
   193   194   195   196   197   198   199   200   201   202   203