140 INSULATION FITTED AT RAFTER LEVEL
      • Manufacturer: Contractor's choice.
          - Product reference: submit proposals.
      • Location: Between rafters.
      • Material: Glass wool to BS EN 13162.
      • Facing: Metal foil.
      • Recycled content: Submit proposals.
      • Thickness: site specific.
      • Installation requirements:
          - General: Insulation to be friction fitted between rafters with no gaps.
          - Joints: Butted, no gaps.
          - Fasteners: Used where necessary to retain insulation and/ or prevent slumping.
          - Vapour control facing (if specified): Fit insulation with facing on warm side.
             Staple overlap (if provided) to underside of rafters; tape joints between adjacent
             overlaps using vapour impermeable adhesive tape.
          - Air space above insulation: Not restricted.
          - Eaves ventilation: Unobstructed.

190 INSULATION FITTED BETWEEN OR TO THE FACE OF STUDS
      • Location: Insert Between studs (site specific).
      • Manufacturer: Contractor's choice.
          - Product reference: submit proposals.
      • Material: Mineral wool to BS EN 13162.
          - Facing: Not required.
      • Recycled content: Contractor's choice.
      • Thickness: site specific.
      • Installation requirements:
          - Joints: Butted, no gaps.
             Fasteners: Use where necessary to retain insulation and/ or prevent slumping.

RotF generic (intermediate) NBS 2014  6118-AEW-XX-XX-NBS-A-01