635 INSTALLING PLASTICS DEPRESSURIZATION SUMPS

•             Position:               15 m maximum from farthest point of area served.

• Area served (maximum): 250 m².

• Base: Compacted hardcore.

   - Thickness: 125 mm.

• Blinding: Sand.

   - Thickness: minimum 35 mm.

640 INSTALLING VENTING HARDCORE LAYERS
      • Filling: Spread and level in 150 mm maximum layers. Thoroughly compact each
          layer whilst maintaining enough voids to allow efficient venting.

650 LAYING HORIZONTAL GEOCOMPOSITE GAS VENTING LAYERS
      • Base: Venting hardcore layer.
      • Jointing: Butt joint. If the geocomposite material includes an integral gas retardant
          membrane, make gastight joints.
      • Fitting: Cut neatly around pile caps, other obstructions or service penetrations.

655 APPLYING VERTICAL GEOCOMPOSITE GAS VENTING LAYERS
      • Apply: Outside external waterproofing membranes.
      • Substrate: site specific.
      • Condition of adjoining surfaces: Clean and dry.
      • Jointing method: Double welted joints sealed with waterproof adhesive.

   COMPLETION

910 INSPECTION OF GROUND GAS COLLECTION AND VENTING SYSTEM
      • Notice for inspection (minimum): 5 days.
      • Defects: Report immediately.

920 DOCUMENTATION
      • Operation and maintenance instructions: Submit.
      • Record drawings: Submit.
          - Number of copies: 2.