9.5 External lighting                                                                                            10.0 Tills

External lighting must be provided to all areas of the DT sequence to 50 Lux throughout. Columns to be sited at  Odema will undertake all till works associated with the multi point DT
least one metre in from kerbs to avoid damage from vehicles.                                                     configuration.

                                                                                                                 10.1 Cash booth

                                                                                                                 Two tills will be located in the CASH both as follows:
                                                                                                                 One till will be the ORDER till for the PRIMARY lane / COD
                                                                                                                 One till will be the cash till

                                                                                                                 A fused spur and socket outlet should be provided, located 400mm AFFL
                                                                                                                 immediately adjacent the position of each till as indicated on the H+K
                                                                                                                 booth drawing

                                                                                                                 10.2 Presenter booth

                                                                                                                 One till will be installed, this will be the ORDER till for the SECONDARY lane
                                                                                                                 / COD

                                                                                                                 Order taking tills are connected directly to the COD units, therefore:

                                                                                                                 The PRIMARY order is ALWAYS taken in the CASH booth
                                                                                                                 The SECONDARY order is ALWAYS taken in the PRESENTER booth

                                                                                                                 A fused spur and socket outlet should be provided, located 400mm AFFL
                                                                                                                 immediately adjacent the position of each till as indicated on the Architects
                                                                                                                 drawing.

                                                                                                                 Acoustic screening is often necessary between the cash booth and the
                                                                                                                 rear of the kitchen and should be reviewed at the design briefing meeting.