Page 69 - Orthopedic Casts and Splints2
P. 69
Performance Steps
NOTE: Alternate method may be used.
b. With opposite hand unroll the plaster or fiberglass 1/2-1 inch and grasp edge with thumb,
index and middle fingers.
NOTE: Placing the thumb under the forward edge of the roll can also be used.
c. Place the plaster or fiberglass roll in bucket of tepid water and remove when bubbles cease
to rise.
CAUTION: Removing the casting material when bubbles are present ensures dry spots will be visible
during application. Dry spots cause integrity break down of the cast.
d. Squeeze the roll together(do not wring the roll).
NOTE: To evenly distribute the water and prevent telescoping of the roll during application gently
squeeze the roll inward.
e. Place the edge of the casting material on the ulnar styloid and begin wrapping around the
wrist two rotations to secure the edge (Refer to figure 3x).
16e
Begin fiberglass casting material at wrist
66