IGEM/G/4 Edition 2
response time
Time interval taken by a control or limiting device to complete a response to a change in state.
rest blocks, relating to a watersealed gasholder
Provision made to support grounded lifts which are fully immersed in the tank water.
Reynolds number (Re)
Dimensionless number that gives a measure of the ratio of internal forces and consequently
quantifies the relative importance of these two types of forces for given flow conditions. It is
used when predicting whether the flow in a pipe is likely to be laminar or turbulent.
riser
Vertical pipe that carries gas between floors within a building.
risk
Likelihood of a specified undesired event occurring within a specified period or in specified
circumstances, expressed as a frequency (rate of occurrence) or as a probability, depending
on the circumstances.
risk assessment
Evaluation of the likelihood of undesired events and the extent of harm or damage, together
with judgements concerning their significance.
room-sealed appliance (type C appliance)
Appliance whose combustion system is sealed from the room in which it is located and which
obtains air for combustion from a ventilated uninhabited space within the premises or directly
from the open air outside the premises and which vents the products of combustion directly to
open air outside the premises.
rope-guided gasholder
Early form of watersealed gasholder in which the upper lift is guided by counterweights and
pulleys.
rotational motor
Motor on a drill rig which rotates the drill string.
route maps
Maps to a scale suitable for showing general details, for example agricultural land, built-up
areas, contours and all special crossings.
routine operation procedure
Formal written document used to control less complex operations.
sacrificial anode
Means of corrosion protection for buried equipment. A mass of relatively electro-positive
metal, such as magnesium or zinc, electrically connected to a pipeline, to ensure that the pipe
is maintained as the cathode in a galvanic cell.
safe area
Area in which an explosive atmosphere consisting of a mixture with air of gas, vapour or mist
is never present.
safe dispersion distance
Distance from a Natural Gas release at which the mean centre line concentration has decayed
to 50% LFL.
safe operating limit (SOL)
Limit beyond which the system should not be taken. It is not the ultimate limit, beyond which
system failure will occur.