Page 42 - igem-g-4 edition 2
P. 42

IGEM/G/4 Edition 2
             security-type valve
             Valve that cannot be closed or opened without the use of a special tool and/or key.

             Se-duct system
             Shared/common flue system where a duct rises vertically through a building. The duct is open
             at the extremities to  draw combustion air into, and take combustion products from, room
             sealed appliances (Type C appliances).

             sense, sensing (gas)
             Refers to the gas pressure sensed at a point.

             sensing line
             Pipe through which pressure from a sensing point is transmitted to a device.

             sensitive location
             Location at which it may be difficult for people to escape or which has concentrations of people
             who would have difficulty in escaping and/or with an increased sensitivity to thermal radiation.

             sensor
             Device that detects a change  of physical parameter  and generates an electrical signal
             corresponding to that change,  for example a photodiode which  detects changes in light
             intensity or a reed switch which responds to change in magnetic field.

             service (pipe)
             Pipe for conveying gas to premises from a  distribution main, being any pipe between a
             distribution main and the outlet of an emergency control valve (ECV).

             service excess flow valve (SEFV)
             Valve installed in a service which will substantially shut off the flow of gas in the event that the
             flow exceeds a defined limit.

             service isolation valve (SIV)
             Valve (other than an emergency control valve (ECV)) for controlling the supply of gas, being a
             valve:
               incorporated in a service (pipe)
               intended for use by a gas transporter (GT)
               not situated inside a building.

             service pipework
             Pipe for distributing gas, for example  liquefied petroleum gas (LPG), to premises from a
             storage vessel to the outlet of an ECV.

             service regulator
             Apparatus for automatic regulation of pressure or of volume flow at a selected point within a
             service (pipe).

             set point
             Value of pressure or flow rate which a regulator or other control device is set to maintain.

             set pressure
             Command value to a pressure regulating system.

             shakedown
             Condition of elastic system response once initial  localised yielding has occurred under  the
             limits of coincident pressure and temperature.

             shared/common flue system
             Flue system serving two or more appliances.





                                                           38