Module 2: High-Pressure CNG Fuel System Components

             Pressure Relief
             Devices (PRDs) and
             Vent Lines















                                                        PRDs              Vent Lines
                                    PRDs protect cylinder from rupture during fire
                                      o  Each cylinder must have at least one PRD
                                    Must be thermally activated
                                    Can be both thermally activated, and pressure activated
                                    Vent caps required

             Fuel System                                 Used to isolate high-pressure fuel during a fuel line break
             Isolation Solenoid                          Opens when the engine is in its startup sequence
             Valve










             Fuel System            Allows first responders to shut off gas to engine in an
             Isolation Manual       emergency
             Valve                  Also known as manual or quarter turn shutoff
                                    Used to isolate the cylinder or cylinders from the remainder
                                    of the high-pressure fuel system for maintenance and repair
                                    of downstream components
                                    If valve is too stiff to turn by hand, it should be replaced