NGV Fueling Instructions
15. The dispenser display indicates the fill is at 100% and gas
flow has stopped, the vehicle is full. Push handle on
dispenser, for the hose you are using, to the off position.
16. While holding the nozzle in on hand, use the other hand to
rotate the handle on the nozzle counterclockwise 90
degrees toward the vent position. Once the nozzle has
vented, continue to rotate the handle until the arrows on
the handle and nozzle are pointing toward each other.
17. Remove nozzle from vehicle receptacle.
18. Push the handle or lever on the dispenser to the off position.
19. Place the nozzle back in dispenser holder/dummy
receptacle.
20. Replace dust cover on vehicle receptacle and close fuel door.
Slide Topic Content Notes
Normal vs. Abnormal Conditions It is considered normal for
an insignificant amount of
gas to escape the
nozzle/receptacle
connection when
disconnected.
May be able to detect the
smell for a brief period of
time.
A scent or audible “hiss” that
lingers is not considered
normal and should be
reported to fueling station
maintenance.