Page 96 - Updated SuDS Design & Evaluation Guide-Newham V3 Spreads
P. 96

Detailed Design  9.5.10  Calculation checklist                              Information for technical                   Parameter      Guidance on design/calculation input                   Information for technical             Detailed Design

                                                                                                                                                                                                    assessment
           Key calculation inputs and outputs should be
                                                                                                                              Modelling
                                                                                                                                             It is not anticipated that  SuDS design will require
                                                                                                                                                                                                     The designer is to justify where
           presented in the ‘Flows and Volumes
                                                                                                                                             modelling of extensive piped systems. In some
                                                                                                                                                                                                     no hydraulic modelling is
                                                                                                                              of the SuDS
           checklist’ (see appendix). The following
                                                                                                                                             instances where the scheme is relatively small and not  undertaken. Calculations/model
                                                                                                                              layout.
           checklist identifies useful calculation checks:
                                                                                                                                                                                                     outputs should be provided to
                                                                                                                                             hydraulically complex standard calculations will be
                                                                                                                                                                                                     support the Flows and Volumes
                                                                                                                                             accepted in lieu of a hydraulic model.  Layout
                           Guidance on design/calculation input
            Parameter
                                                                                                                                                                                                     proforma
                                                                                                                                             drawings should be clearly labelled with the
                                                                                  Confirm the rainfall source and
            Rainfall
                                                                                                                                             Outfalls into receiving sewers or watercourses can be
                           data is used, conversion factors should be applied to
                                                                                  any conversions applied to
            data.          FEH 2013 rainfall data preferred. Where FSR rainfall   assessment                                  Outfall        numbering convention used by models.                    Designer is to indicate whether
                                                                                                                                             at risk of surcharge and lack of free discharge due to
                                                                                                                                                                                                     SuDS storage calculation is
                                                                                                                              design
                           bring in line with FEH rainfall data.                  data.
                                                                                                                                             elevated water levels. This can result in additional    likely to be influenced by high
            Areas          All area of contributing runoff should be represented   Provide a drawing clearly                                 storage being required.  Free discharge should not be  water levels at the point of
            generating     within the storage calculation.                        identifying the areas of surface                           assumed. The risk of surcharge should be assessed       discharge.
            runoff         The designer must justify where a Cv of less than 0.9   runoff contribution within each                           and accounted for within calculations as appropriate.
                           for impermeable area is used for calculations.         subcatchment.                               Long           Long sections will allow detailed consideration of      Long section showing peak
                                                                                  Designer to state Cvs used and              section        levels across the site.                                 water levels.
                                                                                  justify use of Cv less than 0.9.            Erosion        Flows along swales (or other vegetated surfaces) are    Designer to demonstrate that
            Maximum        Statutory authorities e.g. LLFA, sewerage undertaker,   The flow control rate should be            check          at risk from erosion. Peak flow velocities should be    they have considered risk of
            flow control   IDB or EA, might place restrictions on the outfall flow   identified along with the                               less than 1 - 2 l/s.                                    erosion and taken measures to
            rate           rates based on the available capacity of receiving     method for defining the rate.                              Concentrated inlet points are also prone to erosion.    safeguard scheme. Peak flow
                           infrastructure.                                                                                                                                                           velocity calculations to be
            Climate        CCA has been applied within calculations based on      Designer to justify selection of                                                                                   provided as appropriate.
  91        change         design life of development and any applied sensitivity  CCA based on development                   Designing      The design should incorporate overflows at each         Locations of overflows should        92
            allowance      assessment.                                            type and design life.                       for            SuDS component. Hydraulic calculations should           be identified on the layout
            Urban creep Urban creep allowance applied to non-adoptable            Designer to justify selection of            exceedance     demonstrate that overflows have sufficient capacity to  drawing along with proposed
                           impermeable areas on developments where permitted  Urban Creep percentage                                         deal with anticipated flow rates. SuDS layout drawing   exceedance flow route.
                           development is likely to occur.                                                                                   should identify the anticipated flow route for
                                                                                                                                             exceedance events.
            Initial        As a rule of thumb, where the area of development is   Designer to confirm whether
            interception   no greater than 4 times the SuDS wetted area, a 5mm  5mm interception losses have                  Managing       The FRA should identify the potential for flows from    The designer should
                                                                                                                                             offsite. These flows can be unpredictable and difficult
                                                                                                                                                                                                     demonstrate how anticipated
            losses         allowance may be made for interception losses for      been applied in calculation.                flows from
                                  2
                           each m  of development.                                                                            off site.      to quantify. Management of flows through the site       flows from off site will be
            Critical       A range of rainfall durations must be considered when  Designer to demonstrate that                               should not increase flood risk elsewhere.               managed through the site using
            duration       calculating attenuation storage.                       sufficient rainfall durations have                         Detailed modelling to establish the rates of flow       the layout drawing and design
                                                                                  been considered to achieve                                 anticipated would not be considered compulsory (but     statement.
                                                                                  worst case scenario.                                       may be required on a case by case basis).
            Control of     Where the designer demonstrates that water can be      Designer to confirm how                     Consistency  Detailed design of SuDS components should reflect         Drawings should clearly identify
            runoff         ‘lost’ or stored separately Approach 1 can be applied   volume of runoff has been                  of             hydraulic calculations / hydraulic models, taking into   site levels, storage locations and
            volume         for the control of flow being discharge from the site.  controlled.                                calculations   account slopes and low lying levels.                    flow controls with cross
                                                                                                                              and design.    The LLFA will consider design drawings to ensure that   sections and long sections. The
                                                                                                                                             flow control sizing and storage provision is as per     design statement should
                                                                                                                                             calculations.                                           confirm that drawings deliver
                                                                                                                                                                                                     calculated volumes.



           Newham Council SuDS D & E Guide                                                                        © 2020 McCloy Consulting & Robert Bray Associates  Newham Council SuDS D & E Guide                                                                        © 2020 McCloy Consulting & Robert Bray Associates
   91   92   93   94   95   96   97   98   99   100   101