Detailed Design  9.5.4.5  Defining attenuation flow control rates

           LPAs require that SuDS attenuate runoff from
                                                                 In most cases the value derived from IoH124
                                                                 method is similar to FEH methods and due to
           all sites (Greenfield and Brownfield) to
                                                                 its common usage IoH124 values will be
           equivalent greenfield runoff rates. There are 2
                                                                 accepted by the LLFA until FEH methods
           primary methods for controlling rates as
           follows (see Section 6.4.3.5):
                                                                 become more commonplace.
              ■
               Approach 1 - where the volume of runoff
                                                                 Further notes on the application of the
               is controlled, the rate of outflow is
               controlled to the 1 in 1 year and 1 in 100
                                                                     ■
                                                                     FEH ReFHv2 – analysis should ensure that
               year greenfield runoff rate.                      different methods are listed below:
                                                                     there is no urbanised component within
              ■  Approach 2 - where the volume of runoff             the runoff estimate. The flow rate for any
               is not controlled the rate of outflow for all         return period can be derived using the
               rainfall events is controlled to Qbar/Qmed.           ReFHv2 software. The peak rate of
                                                                     catchment runoff is factored back to the
                                                                     site size to establish the greenfield runoff

             NSTS S2,S3 and S6                                       for the site.
                                                                     ■  FEH statistical method requires the
                                                                     designer to establish Qmed (SuDS Manual
                                                                     EQ.24.2) using FEH catchment

           Qmed / Qbar rates are anticipated to be in                descriptors and then undertake a pooling
  81       the region of 2-7 litres per second per                   analysis to derive flow rates if 1 and 100

           hectare (l/s/ha) depending on local rainfall              year flow rates are required.
           and soil characteristics.
                                                                     ■  Establishing Qbar using IoH124 (SuDS
           FEH methods are now preferred for                         Manual EQ.24.3) is based on 50ha area
           estimating Greenfield runoff rates. Care must             input and then factored down to the size
           be taken when selecting the catchment to                  of the site. Where Approach 1 is used, the
           define descriptors to ensure that a small                 1 in 1 and 1 in 100 year Greenfield runoff
           localised catchment is selected.                          rates should be calculated by factoring
                                                                     the Qbar rate using growth curve factors.
           The IoH124 method has been superseded by
                                                                     (SuDS Manual Table 24.2)
           the FEH methods.








                                                        Design Note:

              Regional maps may not be representative of site soil conditions and calculation inputs may
                                              have to be adjusted accordingly.