Page 89 - Enfield SuDS DESIGN & EVALUATION
P. 89

9.5.5  Calculating storage requirements

      Runoff rates and volumes can be managed                water long enough to be discharged either
      by either infiltration or controlled discharge.        into the ground or through flow-controlled
                                                             discharge to a watercourse or sewer.
      Infiltrating runoff through the soil into                                                                    Detailed Design
      underlying geology is the first preference.            Sections 6.4.3.1 and 6.4.3.5 cover the basics
      Where soil, geology or ground conditions do            of infiltration and attenuation storage

      not enable infiltration, then attenuating flows        calculation and should be referred to prior to
      and volumes to controlled discharge rates              progressing with this section where
      would be appropriate.                                  calculation inputs are considered in more
                                                             detail.
      Both infiltration and attenuation require
      storage within the development to hold



      9.5.5.1  Infiltration

      There are two methods for calculating                  CIRIA 156 method
      temporary storage for infiltration.

      The CIRIA 156 method assumes that there
      will be infiltration through the base and sides
      of the structure on an ongoing basis. Factors
      of safety ranging between 1.5 and 10
      depending on the consequence of failure,                                                                     84

      and the area draining to the infiltration                          Factor of safety applied
      structure (see C753 Table 25.2), are allocated
      to account for potentially reduced infiltration
      over time.

      The BRE 365 method assumes that the base
      of the system, such as traditional soakaway,           BRE 365 method
      will silt up and therefore infiltration is only
      calculated through the vertical sides. The
      assumption of no infiltration through the
      base is the equivalent of the factor of safety.

      It is noted that various systems such as
      permeable pavement are resilient to siltation.             Assume no infiltration through the base

      However, infiltration schemes are not
      straight-forward and sites which are free
      draining can quickly become compacted
      during the construction phase.



      Enfield Council SuDS D & E Guide                                                                            © 2018 McCloy Consulting & Robert Bray Associates
   84   85   86   87   88   89   90   91   92   93   94