Detailed Design  9.11.5 Storage structures                  The introduction of geocellular structures is              In addition, to the statements from the SuDS           Where underground storage is preferred                Detailed Design
                                                                                                                             Manual the following should also be
                                                                                                                                                                                    after a full exploration of the available
           Attenuation storage in underground
                                                                                                                             considered:
                                                                                                                                                                                    options the designer should demonstrate
                                                                  still relatively recent in the construction
           structures is currently utilised throughout
                                                                                                                                                                                    that:
                                                                                                                                ■
                                                                                                                                 There are risks of structural failure due to
           construction industry with may applications
                                                                  industry and the long term implications of
                                                                                                                                 construction loading, which may exceed
                                                                                                                                                                                       ■
                                                                                                                                                                                       Robust silt removal has been provided
           being in the form of geocellular tanks. Simply
                                                                  their use is still being understood. The SuDS
                                                                                                                                 design life loading that the designer may
                                                                                                                                                                                       through means of filtration (bioretention,
           providing underground tanks should not be
                                                                  manual (Section 21.1) clarifies that:
                                                                                                                                 not be aware of.
                                                                                                                                                                                       permeable pavement) or other source
           confused with a full SuDS approach; however,
           they can form part of the SuDS management
                                                                                                                                ■
                                                                                                                                 There are a wide range of attenuation
                                                                                                                                                                                       not be accepted as a demonstrable form
           train.
                                                                                                                                 products each with its own loading
                                                                                                                                                                                       of silt removal. The SuDS manual (Section
                                                                                                                                 characteristics. Surety must be provided              control SuDS components. Catchpits will
              ■  Where storage is in an underground tank,            ■  Geocellular systems and plastic arches                   that a specified product is not swapped               4.1) clarifies that sediments within
               failures and blockages tend not to get                tend not to be easily accessible for                        for one of inferior quality during the                catchpits can be remobilised and washed
               noticed, which may mean that the                      inspection or cleaning, so very effective                   construction phase.                                   downsteam. Equally, gullypots are
               consequences of failure can be                        upstream treatment is required to ensure                   ■                                                      suggested by Table 26.15 to provide
               catastrophic.                                         adequate sediment removal.                                  Guarantees and warranties are dependent               negligible to zero treatment (Ellis et al,
                                                                                                                                 on the survival of product manufacturers.             2012).
              ■  Underground storage tanks do not have               ■  The structural design of geocellular
               inherent treatment capacity and therefore             systems tends to be more complex and                                                                              ■  Underground structures require structural
               require integration with a SuDS                       there have been a number of collapses of                                                                          design consideration even if they are not
                                                                                                                                                                                       receiving vehicular loading. CIRIA report
               management train.                                     these systems caused by inadequate
                                                                     design. (see Mallett et al, 2014, and                                                                             C737 outlines the design requirements for
                                                                                                                                                                                       geocellular tanks.  The SuDS Manual
                                                                     O’Brien et al, in press) (see C737)
  137                                                                                                                                                                                  (Table 21.1) provides a summary of the             138
                                                                                                                                                                                       structural design requirements using a risk
                                                                                                                                                                                       classification system (Scored between
                                                                                                                                                                                       0-3). Designers should demonstrate that
                                                                                                                                                                                       the classification system has been
                                                                                                                                                                                       followed and present the appropriate level
                                                                                                                                                                                       of design information accordingly.











                                                                                                                                                                          Design Note:

                                                                                                                                Where the stated design life of the  tank does not meet the design life of the development,
                                                                                                                                  the design should demonstrate how the structure will be replaced whist maintaining the
                                                                                                                                functionality of the drainage system and the scheme. Consideration should also be given to
                                                                                                                                                funding mechanism for undertaking these replacement works.