Page 84 - Newham SuDS DESIGN & EVALUATION GUIDE
P. 84

Detailed Design  9.5.4  Calculation inputs                                                                             9.5.4.3  Making allowances for interception losses                                                           Detailed Design

                                                                                                                             As a rule of thumb, where the total wetted
           9.5.4.1  Rainfall data selection
                                                                                                                             area of SuDS components equates to at least
           Rainfall depths and intensities for a range of
                                                                                                                             25% of the development area (all buildings
           return periods and storm durations is one of
                                                                                                                             and hard surfaces) then it is acceptable to
           the key calculation inputs.
                                                                                                                             make an allowance for interception losses.
                                                                                                                                                                                     For more detailed analysis methods
           The choice of rainfall data can have a
                                                                                                                             This loss can be applied within storage
           significant effect on the volume of storage
           calculated.
                                                                                                                             by 5mm.
           FEH 2013 rainfall data is considered the most                                                                     calculations by reducing the rainfall depths            see SuDS Manual Section 24.8
           up-to-date data availabale and therefore
           recommended for use.                                                                                              9.5.4.4  Defining infiltration rates
                                                                   FEH 2013 rainfall data can be sourced
           Where FSR rainfall values are used the                                                                            The specified infiltration test methodology            For example, tests should not be undertaken
           designer must demonstrate that rainfall                 online at fehweb.ceh.ac.uk                                should be representative of the proposed               1.5m below ground level when shallow
           values are consistent with FEH 2013 data.                                                                         design.                                                infiltration is proposed from permeable
                                                                                                                                                                                    pavement, rain gardens or basins which will
                                                                                                                             The depth of water and depth of test trench
                                                                                                                                                                                    be located close to ground surface.
                                                                                                                             below ground level should seek to replicate
                                                                                                                             the attributes of the proposed infiltration
           9.5.4.2  Defining runoff coefficients (Cv)                                                                        system.


  79       In extreme rainfall conditions the losses              Some modelling software packages contain                                                                                Bromsgrove Civic Centre re-development.         80
           anticipated from hard development surfaces             ‘Default’ Cv values (0.75 Summer, 0.84                                                      Permeable block and slab paving with a central grass detention basin
           such as roofs or paved areas are anticipated           Winter) which assume that there will be 25%                                                                    provide a fully integrated infiltrating SuDS scheme.
           to be minimal.                                         summer and 16% winter losses from hard
                                                                  surfaces.
           The designer must evaluate the runoff
           coefficient (Cv) for the types of surfaces             These default values should not be used for
           contributing runoff to the storage location.           storage estimation calculations.
           Sewers for adoption (Section C5.1)
                                                                  The designer must justify where a Cv of less
           recommends assuming 100% runoff from
                                                                  than 0.9 is used for calculations.
           impermeable areas which equates to a Cv of
           1.0.                                                   Where a reasonable amount of permeable
                                                                  surface contribution to SuDS storage, then
           Runoff coefficients of 0.95 for roofs and 0.9
                                                                  this should be considered within calculations.
           for paved areas would be considered
                                                                  The ‘UKSuDS’  website was recently updated
           acceptable by the LLFA where drainage is
                                                                  to allow input for permeable surface runoff
           not being adopted by a Water and Sewerage
                                                                  contribution within attenuation calculations.
           Company (Thames Water).






           London Borough of Newham SuDS D & E Guide                                                     © 2018 McCloy Consulting & Robert Bray Associates  London Borough of Newham SuDS D & E Guide                                                     © 2018 McCloy Consulting & Robert Bray Associates
   79   80   81   82   83   84   85   86   87   88   89