Page 80 - Newham SuDS DESIGN & EVALUATION GUIDE
P. 80

Detailed Design                                                                                                        9.4  Critical levels                                      ■   ■  Areas contributing to a storage             Detailed Design


                                                                                                                             Levels are important in any drainage system
                                                                                                                                                                                       component should not be situated below
                                                                                                                             and especially so for surface based SuDS.
                                                                                                                                                                                       the top level of storage as they may flood
                                                                                                                             The proposed surface levels should align with
                                                                                                                                                                                       prior to the storage being filled.
                                                                                                                             the modified flow route analysis in providing
                                                                                                                             a flow path across the site and storage
                                                                                                                                                                                       For storage components that are sloping,
                                                                                                                             volumes can be significantly affected by
                                                                                                                             inaccurate levels.
                                                                                                                                                                                       basins, the ‘effective’ storage should be
                                                                                                                                                                                       determined rather than the entire volume
                                                                                                                             The following levels should be evaluated                  such as permeable pavements or linear
                                                                                                                             when developing or reviewing a design:                    of the structure.

                                                                                                                                ■  The flow control invert level relative to           ■  A review of site levels should not identify
                                                                                                                                 storage - the flow control should not be              any obvious obstructions along

                                                                                                                                 situated above the base level of the                  exceedance flow paths.
                                                                                                                                 storage component unless there is a
                                                                                                                                                                                                         Note :
                                                                                                                                 requirement for permanent or semi-
                                                                                                                                 permanent water.                                    The LLFA will carry out a high-level review
                                                                                                                                                                                         of levels only - Liability for design is
                                                                                                                                ■  The overflow level should demonstrate
                                                                                                                                                                                         retained by the designer in all cases.
                                                                                                                                 that the required volume of storage is
                                                                                                                                 contained between the flow control invert
                                                                                                                                 level and the overflow level.                                      Grey to Green project, Sheffield.
  75                                                                                                                                                                                   The 3 flow control criteria: low flow, overflow    76
                                                                                                                             Facing: Accurate levels were critical at Bewdley                     and exceedance are demonstrated
                                                                                                                             School Science Block.                                                                    elegantly here.



































           London Borough of Newham SuDS D & E Guide                                                     © 2018 McCloy Consulting & Robert Bray Associates  London Borough of Newham SuDS D & E Guide                                                     © 2018 McCloy Consulting & Robert Bray Associates
   75   76   77   78   79   80   81   82   83   84   85