BUILDING PLANNING



                    away during design flood conditions without caus-  R324.2 Solar thermal systems. Solar thermal systems shall
                    ing  damage  to  the  building  or  structure,  including  be designed and installed in accordance with Chapter 23 and
                    foundation.                                   the International Fire Code.
                  3. Be retractable, or able to be raised to or above the  R324.3 Photovoltaic systems. Photovoltaic systems shall be
                    lowest floor elevation, provided that the ability to be  designed and installed in accordance with Sections R324.3.1
                    retracted or raised prior to the onset of flooding is  through R324.7.1, NFPA 70 and the manufacturer’s installa-
                    not contrary to the means of egress requirements of  tion instructions.
                    the code.                                        R324.3.1  Equipment  listings.  Photovoltaic  panels  and
                  4. Be  designed  and  constructed  to  resist  flood  loads  modules shall be listed and labeled in accordance with UL
                    and minimize transfer of flood loads to the building  1703. Inverters shall be listed and labeled in accordance
                    or structure, including foundation.              with UL 1741. Systems connected to the utility grid shall
                                                                     use inverters listed for utility interaction.
                  Areas below stairways and ramps shall not be enclosed
               with walls below the design flood elevation unless such  R324.4  Rooftop-mounted  photovoltaic  systems.  Rooftop-
               walls  are  constructed  in  accordance  with  Section  mounted photovoltaic panel systems installed on or above the
               R322.3.5.                                          roof covering shall be designed and installed in accordance
                                                                  with this section.
               R322.3.8  Decks  and  porches.  Attached  decks  and
               porches shall meet the elevation requirements of Section  R324.4.1  Structural  requirements.  Rooftop-mounted
               R322.3.2  and  shall  either  meet  the  foundation  require-  photovoltaic panel systems shall be designed to structur-
               ments of this section or shall be cantilevered from or knee  ally support the system and withstand applicable gravity
               braced to the building or structure. Self-supporting decks  loads  in  accordance  with  Chapter  3.  The  roof on  which
               and porches that are below the elevation required in Sec-  these  systems  are  installed  shall  be  designed  and  con-
               tion R322.3.2 shall not be enclosed by solid, rigid walls,  structed to support the loads imposed by such systems in
               including walls designed  to break  away. Self-supporting  accordance with Chapter 8.
               decks  and  porches  shall  be  designed  and  constructed  to  R324.4.1.1 Roof load. Portions of roof structures not
               remain in place during base flood conditions or shall be  covered  with  photovoltaic panel  systems  shall  be
               frangible and break away under base flood conditions.   designed for dead loads and roof loads in accordance
                                                                       with  Sections  R301.4  and  R301.6.  Portions  of  roof
               R322.3.9  Construction  documents.  The  construction
               documents  shall  include  documentation  that  is  prepared  structures  covered  with  photovoltaic panel systems
                                                                       shall be designed for the following load cases:
               and  sealed  by  a  registered  design professional  that  the
               design and methods of construction to be used meet the    1. Dead  load  (including  photovoltaic panel  weight)
               applicable criteria of this section.                         plus  snow  load  in  accordance  with  Table
                                                                            R301.2(1).
               R322.3.10 Tanks. Underground tanks shall be anchored
               to prevent flotation, collapse and lateral movement under  2. Dead load (excluding photovoltaic panel weight)
               conditions of the base flood. Above-ground tanks shall be    plus  roof  live  load  or  snow  load,  whichever  is
               installed  at  or  above  the  elevation  required  in  Section  greater, in accordance with Section R301.6.
               R322.3.2.  Where  elevated  on  platforms,  the  platforms  R324.4.1.2 Wind load. Rooftop-mounted photovoltaic
               shall be cantilevered from or knee braced to the building  panel  or  module  systems  and  their  supports  shall  be
               or shall be supported on foundations that conform to the  designed and installed to resist the component and clad-
               requirements of Section R322.3.                         ding  loads  specified  in Table R301.2(2),  adjusted for
                                                                       height  and  exposure  in  accordance  with  Table
                                                                       R301.2(3).
                              SECTION R323
                            STORM SHELTERS                           R324.4.2 Fire classification. Rooftop-mounted photovol-
                                                                     taic panel systems shall have the same fire classification as
             R323.1 General. This section applies to storm shelters where  the roof assembly required in Section R902.
             constructed  as  separate  detached  buildings  or  where  con-  R324.4.3 Roof penetrations. Roof penetrations shall be
             structed  as  safe  rooms  within  buildings  for  the  purpose  of  flashed and sealed in accordance with Chapter 9.
             providing refuge from storms that produce high winds, such
             as  tornados  and  hurricanes.  In  addition  to  other  applicable  R324.5  Building-integrated  photovoltaic  systems.  Build-
             requirements in this code, storm shelters shall be constructed  ing-integrated photovoltaic systems that serve as roof cover-
             in accordance with ICC/NSSA-500.                     ings  shall  be  designed  and  installed  in  accordance  with
                                                                  Section R905.
                                                                     R324.5.1  Photovoltaic  shingles.  Photovoltaic  shingles
                               SECTION 324                           shall comply with Section R905.16.
                         SOLAR ENERGY SYSTEMS
                                                                     R324.5.2  Fire  classification.  Building-integrated photo-
             R324.1 General. Solar energy systems shall comply with the  voltaic systems  shall  have  a  fire  classification  in  accor-
             provisions of this section.                             dance with Section R902.3.