Page 120 - 2018_IRC
P. 120

FOUNDATIONS



                         BOTTOM (SOLE) PLATE
                         ATTACHMENT PER               3½" MIN CONCRETE
                          SECTION R403.1.6            SLAB PER SECTION R506.1               BEARING WALL
                  MIN CLEARANCE                                                             WALL LINE
                  PER SECTIONS
                  R404.1.6 AND                                                              3½" MIN CONCRETE SLAB
                  R317.1 TYP                                                                PER SECTION R506.1
                  12″ MIN DEPTH
                  OR GREATER FOR
                  FROST PROTECTION
                  PER SECTIONS
                  R403.1.4 AND
                  R403.1.4.1 TYP              W
                                                                                  W

                        MONOLITHIC SLAB-ON-GROUND                        THICKENED SLAB-ON-GROUND FOOTING
                     1  WITH TURNED-DOWN FOOTING                      2  AT BEARING WALLS OR BRACED WALL LINES
                                                                         SCALE: NOT TO SCALE
                        SCALE: NOT TO SCALE
                                   3½" MIN CONCRETE SLAB
                                   PER SECTION R506.1
                    MIN CLEARANCE                                                         INTERIOR
                    PER SECTIONS
                    R404.1.6 AND
                    R317.1 TYP
                                                                                             CMU STEM WALL
                                                     CMU STEM WALL
                  12″ MIN DEPTH PER         P    P                               P     P
                  SECTION R403.1.4
                  OR GREATER FOR
                  FROST PROTECTION      T                                    T
                  PER SECTION
                  R403.1.4.1 TYP
                                              W                                     W

                        SLAB-ON-GROUND WITH                              BASEMENT OR CRAWL SPACE WITH
                     3  MASONRY STEM WALL AND SPREAD FOOTING           4  MASONRY WALL AND SPREAD FOOTING
                        SCALE: NOT TO SCALE                              SCALE: NOT TO SCALE
                      CONCRETE STEM
                      WALL THICKNESS
                      PER SECTION R404.1.3
                                                     INTERIOR                              INTERIOR

                   CONCRETE STEM WALL
                                            P    P                                         CONCRETE STEM AND
                                                                                           FOOTING COMBINED
                                                                                           (MONOLITHIC POUR)
                    CONCRETE FOOTING PLACED         T
                    PRIOR TO STEM
                                              W                                    W

                        BASEMENT OR CRAWL SPACE WITH                     BASEMENT OR CRAWL SPACE WITH
                        CONCRETE WALL AND SPREAD FOOTING                 FOUNDATION WALL BEARING DIRECTLY ON SOIL
                     5                                                 6
                        SCALE: NOT TO SCALE                              SCALE: NOT TO SCALE
                 For SI: 1 inch = 25.4 mm.
                 W = Width of footing, T = Thickness of footing and P = Projection per Section R403.1.1
                 NOTES:
                 a. See Section R404.3 for sill requirements.
                 b. See Section R403.1.6 for sill attachment.
                 c. See Section R506.2.3 for vapor barrier requirements.
                 d. See Section R403.1 for base.
                 e. See Figure R403.1.3 for additional footing requirements for structures in SDC D , D  and D  and townhouses in SDC C.
                                                                                1
                                                                                      2
                                                                             0
                 f. See Section R408 for under-floor ventilation and access requirements.

                                                         FIGURE R403.1(1)
                       PLAIN CONCRETE FOOTINGS WITH MASONRY AND CONCRETE STEM WALLS IN SDC A, B AND C a, b, c, d, e, f


             2018 INTERNATIONAL RESIDENTIAL CODE ®                                                                95