Page 121 - 2018_IRC
P. 121

FOUNDATIONS

















                  PRESSURE-PRESERVATIVE-TREATED




                                                                     FLASHING
                                                                     2 × 6 IN. STUD INSULATED
                          FIELD-APPLIED 2 × 6 IN. TOP PLATE          AS APPROPRIATE AND WARM SIDE
                                                                     VAPOR BARRIER
                                       2 × 6 IN. TOP PLATE
                                                                     2-IN. AIR GAP
                                                                     1-IN.-THICK PRESSURE-PRESERVATIVE-
                                                                     TREATED LUMBER OR PLYWOOD STRIP
                                                                     PROTECTING TOP OF POLYETHYLENE FILM
                                                                                        FINISH GRADE SLOPE  / IN.
                                                                                                         1
                                                                                                          2
                                                                                        PER FOOT, MIN. 6 FT. FROM
                                                                                        WALL
                                                                                       PRESSURE-PRESERVATIVE-
                                                                                       TREATED PLYWOOD
                                                                                       (SEE TABLE R404.2.3)
                                4 FT. (MAX. BACKFILL)
                                                                                       6 MIL POLYETHYLENE FILM
                                                                                       6 MIL POLYETHYLENE FILM
                                                                                       ON CRUSHED STONE OR
                                                                                       GRAVEL BACKFILL
                         s
           MIN. 3.5-IN. CONCRETE SLAB WITH
           VAPOR BARRIER AND OPTIONAL                                             PRESSURE-PRESERVATIVE-
           1-IN. SCREED BOARD                                                     TREATED 2 × 6 IN. BOTTOM
                                                                                  PLATE

                                 6 IN.                                             PRESSURE-PRESERVATIVE-
                                                      4 IN.        4 IN.           TREATED 2 × 8 IN. FOOTING
                                                                                   PLATE
                      4 IN. GRAVEL OR CRUSHED               16 IN.
                      STONE FILL UNDER FLOOR
                      (SEE SECTION R403.2)




         For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 mil = 0.0254.

                                                     FIGURE R403.1(2)
                                    PERMANENT WOOD FOUNDATION BASEMENT WALL SECTION












         96                                                                  2018 INTERNATIONAL RESIDENTIAL CODE  ®
  Copyrighted © 2017 by, or licensed to, ICC (ALL RIGHTS RESERVED); licensed to UL, LLC pursuant to License Agreement with ICC. No further reproductions authorized or distribution authorized.
  ANY UNAUTHROIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT; AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.
   116   117   118   119   120   121   122   123   124   125   126