Page 153 - 2018_IRC
P. 153
FOUNDATIONS
MIN. NINE 16D NAILS
GALVANIZED OR STAINLESS STEEL STRAPS, PER STRAP
1
MIN. 2 / IN. WIDE BY 12 GAGE THICK,
16 TREATED
MIN. 2 IN. FROM EDGE OF PIER, TYP. SILL PLATE
PIERS SPACED NOT
MORE THAN 6 FT O.C.,
TYP.
MIN.8IN. X16IN.
MASONRY PIER, TYP.
MIN. TWO 9 GAGE BOX TIES
OR TWO MASONRY HEADERS
AT 8 IN. O.C. EACH PIER
STRAPS ANCHORED WITH 90 DEGREE HOOK, MIN.
TWO STRAPS PER PIER, MIN. 4 IN. EMBEDMENT INTO
FOOTING, MIN. 1.75 IN. HORZ. LEG EXTENSION
DOUBLE RIM JOISTS
MIN. 18 GAGE PLATE
CONNECTORS AT
MAX. 12 IN. O.C. (TYP.)
MIN. 4 IN. MASONRY
CURTAIN WALL
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 degree = 0.0175 rad.
FIGURE R404.1.5(1)
FOUNDATION WALL CLAY MASONRY CURTAIN WALL WITH CONCRETE MASONRY PIERS
128 2018 INTERNATIONAL RESIDENTIAL CODE ®
Copyrighted © 2017 by, or licensed to, ICC (ALL RIGHTS RESERVED); licensed to UL, LLC pursuant to License Agreement with ICC. No further reproductions authorized or distribution authorized.