FOUNDATIONS



               R404.1.7 Backfill placement. Backfill shall not be placed  R404.1.9.5  Masonry  piers  in  flood  hazard  areas.
               against the wall until the wall has sufficient strength and  Masonry piers for dwellings in flood hazard areas shall
               has been anchored to the floor above, or has been suffi-  be designed in accordance with Section R322.
               ciently braced to prevent damage by the backfill.  R404.2  Wood  foundation  walls.  Wood  foundation  walls
                  Exception: Bracing is not required for walls supporting  shall be constructed in accordance with the provisions of Sec-
                  less than 4 feet (1219 mm) of unbalanced backfill.  tions R404.2.1 through R404.2.6 and with the details shown
                                                                  in Figures R403.1(2) and R403.1(3).
               R404.1.8 Rubble stone masonry. Rubble stone masonry
               foundation  walls  shall  have  a  minimum  thickness  of  16  R404.2.1  Identification.  Load-bearing  lumber  shall  be
               inches (406 mm), shall not support an unbalanced backfill  identified  by  the  grade  mark  of  a  lumber  grading  or
               exceeding 8 feet (2438 mm) in height, shall not support a  inspection agency that has been approved by an accredita-
               soil pressure greater than 30 pounds per square foot per  tion  body  that  complies  with  DOC  PS  20.  In  lieu  of  a
               foot (4.71 kPa/m), and shall not be constructed in Seismic  grade mark, a certificate of inspection issued by a lumber
               Design Categories  D ,  D , D  or townhouses in  Seismic  grading or inspection agency meeting the requirements of
                                       2
                                    1
                                 0
               Design Category C, as established in Figure R301.2(2).  this section shall be accepted. Wood structural panels shall
                                                                     conform to DOC PS 1 or DOC PS 2 and shall be identified
               R404.1.9 Isolated masonry piers. Isolated masonry piers  by a grade mark or certificate of inspection issued by an
               shall be constructed in accordance with this section and  approved agency.
               the general masonry construction requirements of Section
               R606. Hollow masonry piers shall have a minimum nomi-  R404.2.2  Stud size.  The  studs  used  in foundation  walls
               nal thickness of 8 inches (203 mm), with a nominal height  shall be 2-inch by 6-inch (51 mm by 152 mm) members.
               not exceeding four times the nominal thickness and a nom-  Where spaced 16 inches (406 mm) on center, a wood spe-
               inal length not exceeding three times the nominal thick-  cies with an F  value of not less than 1,250 pounds per
                                                                                 b
               ness. Where hollow masonry units are solidly filled with  square inch (8619 kPa) as listed in ANSI AWC NDS shall
               concrete or grout, piers shall be permitted to have a nomi-  be used. Where spaced 12 inches (305 mm) on center, an
               nal height not exceeding ten times the nominal thickness.  F  of not less than 875 psi (6033 kPa) shall be required.
                                                                      b
               Footings for isolated masonry piers shall be sized in accor-  R404.2.3 Height of backfill. For wood foundations that are
               dance with Section R403.1.1.                          not designed and installed in accordance with AWC PWF,
                                                                     the height of backfill against a foundation wall shall not
                  R404.1.9.1  Pier  cap.  Hollow  masonry  piers  shall  be
                  capped  with  4  inches  (102  mm)  of  solid  masonry  or  exceed 4 feet (1219 mm). Where the height of fill is more
                  concrete, a masonry cap block, or shall have cavities of  than 12 inches (305 mm) above the interior grade of a crawl
                  the  top  course  filled  with  concrete  or  grout.  Where  space or floor of a basement, the thickness of the plywood
                  required,  termite  protection  for  the  pier  cap  shall  be  sheathing shall meet the requirements of Table R404.2.3.
                  provided in accordance with Section R318.          R404.2.4 Backfilling. Wood foundation walls shall not be
                                                                     backfilled  until  the  basement  floor  and  first  floor  have
                  R404.1.9.2 Masonry piers supporting floor girders.
                  Masonry piers supporting wood girders sized in accor-  been constructed or the walls have been braced. For crawl
                                                                     space construction, backfill or bracing shall be installed on
                  dance  with  Tables  R602.7(1)  and  R602.7(2)  shall  be  the  interior  of  the  walls  prior  to  placing  backfill  on  the
                  permitted  in  accordance  with  this  section.  Piers  sup-  exterior.
                  porting girders for interior bearing walls shall have a
                  minimum nominal dimension of 12 inches (305 mm)    R404.2.5  Drainage  and  dampproofing.  Wood  founda-
                  and a maximum height of 10 feet (3048 mm) from top  tion basements shall be drained and dampproofed in accor-
                  of footing to bottom of sill plate or girder. Piers sup-  dance with Sections R405 and R406, respectively.
                  porting girders for exterior bearing walls shall have a  R404.2.6  Fastening.  Wood  structural  panel  foundation
                  minimum nominal dimension of 12 inches (305 mm)    wall sheathing shall be attached to framing in accordance
                  and a maximum height of 4 feet (1220 mm) from top of  with Table R602.3(1) and Section R402.1.1.
                  footing to bottom of sill plate or girder. Girders and sill
                  plates shall be anchored to the pier or footing in accor-  R404.3 Wood sill plates. Wood sill plates shall be not less
                  dance  with  Section  R403.1.6  or  Figure  R404.1.5(1).  than 2-inch by 4-inch (51 mm by 102 mm) nominal lumber.
                  Floor girder bearing shall be in accordance with Sec-  Sill  plate  anchorage  shall  be  in  accordance  with  Sections
                  tion R502.6.                                    R403.1.6 and R602.11.
                  R404.1.9.3  Masonry  piers  supporting  braced  wall  R404.4 Retaining walls. Retaining walls that are not later-
                                                                  ally supported at the top and that retain in excess of 48 inches
                  panels. Masonry piers supporting braced wall panels  (1219 mm) of unbalanced fill, or retaining walls exceeding 24
                  shall  be  designed  in  accordance  with  accepted  engi-
                  neering practice.                               inches (610 mm) in height that resist lateral loads in addition
                                                                  to soil, shall be designed in accordance with accepted engi-
                  R404.1.9.4  Seismic  design  of  masonry  piers.  neering practice to ensure stability against overturning, slid-
                  Masonry piers in dwellings located in Seismic Design  ing, excessive foundation pressure and water uplift. Retaining
                  Category  D ,  D   or  D ,  and  townhouses  in  Seismic  walls shall be designed for a safety factor of 1.5 against lat-
                            0
                               1
                                     2
                  Design  Category  C,  shall  be  designed  in  accordance  eral sliding and overturning. This section shall not apply to
                  with accepted engineering practice.             foundation walls supporting buildings.