Page 174 - 2018_IRC
P. 174

FLOORS





                                                C.L.                   C.L.
                                                         24 IN. MIN.                 10 IN. MIN.









                                                                       1
                                                1
                                               4 / IN.                4 / IN.      CENTERLINE OF WEB
                                                                        2
                                                 2
                                               MAX.                   MAX.
                         1
                        2 / IN. MAX.
                         2
                                                                         BEARING CONDITION
             For SI: 1 inch = 25.4 mm.
                                                         FIGURE R505.2.6.1
                                                      FLOOR JOIST WEB HOLES

                  R505.2.6.3  Hole  patching.  Patching  of  web  holes  in  R505.3.1(5) or R505.3.1(6). Anchor bolts shall be located
                  floor joists not conforming to the requirements in Sec-  not more than 12 inches (305 mm) from corners or the ter-
                  tion R505.2.6.1 shall be permitted in accordance with  mination of bottom tracks. Continuous cold-formed steel
                  either of the following methods:                   joists  supported  by  interior  load-bearing  walls  shall  be
                    1. Framing members shall be replaced or designed  constructed  in  accordance  with  Figure  R505.3.1(7).
                       in  accordance  with  accepted  engineering  prac-  Lapped  cold-formed  steel  joists  shall  be  constructed  in
                       tices where web holes exceed the following size  accordance with Figure R505.3.1(8). End floor joists con-
                       limits:                                       structed on foundation walls parallel to the joist span shall
                                                                     be doubled unless a C-shaped bearing stiffener, sized in
                         1.1. The depth of the hole, measured across  accordance with Section R505.3.4, is installed web-to-web
                             the  web,  exceeds  70 percent  of the  flat  with the floor joist beneath each supported wall stud, as
                             width of the web.                       shown  in  Figure  R505.3.1(9).  Fastening  of  cold-formed
                         1.2. The length of the hole, measured along  steel  joists  to  other  framing  members  shall  be  in  accor-
                             the web, exceeds 10 inches (254 mm) or  dance with Section R505.2.5 and Table R505.3.1(2).
                             the  depth  of  the  web,  whichever  is
                             greater.                                                     JOIST
                    2. Web holes not exceeding the dimensional require-
                       ments  in  Section  R505.2.6.3,  Item  1,  shall  be               SOLID STEEL PLATE,
                       patched  with  a  solid  steel  plate,  stud  section  or          C-SHAPED OR TRACK,
                       track  section  in  accordance  with  Figure                       MIN. THICKNESS AS
                                                                                          JOIST
                       R505.2.6.3. The steel patch shall, as a minimum,
                       be of the same thickness as the receiving member
                       and  shall  extend  not  less  than  1  inch  (25  mm)
                       beyond all edges of the hole. The steel patch shall
                       be fastened to the web of the receiving member
                       with No. 8 screws spaced not more than 1 inch (25
                       mm) center-to-center along the edges of the patch
                                                1
                       with minimum edge distance of  /  inch (12.7 mm).
                                                 2
             R505.3  Floor  construction.  Cold-formed  steel  floors  shall  NO. 8 SCREWS
                                                                   SPACED AT 1 IN. O.C.
             be constructed in accordance with this section.       (TYP.)
               R505.3.1 Floor-to-foundation or load-bearing wall con-
               nections.  Cold-formed  steel-framed  floors  shall  be
               anchored to foundations, wood sills or load-bearing walls
               in  accordance  with  Table  R505.3.1(1)  and  Figure  For SI: 1 inch = 25.4 mm.
               R505.3.1(1),  R505.3.1(2),  R505.3.1(3),  R505.3.1(4),
                                                                                    FIGURE R505.2.6.3
                                                                              FLOOR JOIST WEB HOLE PATCH



             2018 INTERNATIONAL RESIDENTIAL CODE ®                                                               149
  Copyrighted © 2017 by, or licensed to, ICC (ALL RIGHTS RESERVED); licensed to UL, LLC pursuant to License Agreement with ICC. No further reproductions authorized or distribution authorized.
  ANY UNAUTHROIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT; AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.